Municipality · Colorado

Crested Butte

The ordinance has been retrieved, read and turned into structured rules.
18
Districts
101
Extracted rules
596
Standards
7
Chapters read

Zoning districts

18 districts, grouped by category.

General provisions

83 rules that bind every district rather than one — sign regulations, parking, floodplain and the rest of the code’s citywide chapters.

Appendix J, Paragraph 176 standards

All utility lines shall be placed underground in accordance with applicable Town requirements.

Article 15, Sec. 16-15-3019 standards

Landscaping shall conform to the landscape plan submitted pursuant to Section 18-13-20(a) ...

Article 16-16, Sec. 16-16-40 to 16-16-1009 standards

Underground parking is allowed... The usable square footage ratio for the site may be increased by 270 sq ft per underground parking space.

Article 16-17, Sec. 16-17-30 to 16-17-609 standards

No high intensity discharge lights may be utilized in any exterior application within the Town.

Article 16-18, Sec. 16-18-10 to 16-18-206 standards

No sign shall be erected, constructed, altered, remodeled or changed until a permit therefor has been issued.

Article 16-5, Division 2, 'T' District, Secs. 16-5-20 through 16-5-708 standards

Permitted uses: hotels, lodges, motels and resorts. Conditional uses include residential units, restaurants, etc. Lot area 5,000 sq ft, height 35 ft, FAR 0.66, open space 25%.

Article 17-10 and 17-1135 standards

Subdivision standards for streets, utilities, drainage, trails, sidewalks, and floodplain.

Definitions1 standards

All high quality wetlands require a buffer of at least one hundred (100) feet from a change in land use.

Definitions10 standards

Home occupation means any commercial use carried on within a dwelling which is ... conducted without the employment of individuals other than the occupants of the dwelling.

Definitions19 standards

Parking, Off-Street: any parking space not less than nine (9) feet in width, eighteen (18) feet in length and seven (7) feet in height

Definitions - Wetland study area1 standards

Wetland study area includes the lands within the proposed subdivision and within one hundred (100) feet of the proposed subdivision.

Sec. 16-10-20

It is the intent of this Article to provide for review of all development located above the 'Excessive Slope Line' designated on the Official Zoning Map...

Sec. 16-11-230(1)4 standards

New construction and substantial improvement of any residential structure shall have the lowest floor (including basement), electrical, heating, ventilation, plumbing and air conditioning equipment and other service facilities (including ductwork) elevated to one (1) foot above the base flood elevation.

Sec. 16-11-230(2)3 standards

New construction and substantial improvements of any commercial, industrial or other nonresidential structure shall either have the lowest floor ... elevated to one (1) foot above the base flood elevation or ... be designed so that ... the structure is watertight with walls substantially impermeable to the passage of water ...

Sec. 16-11-230(4)2 standards

be elevated on a permanent foundation such that the lowest floor of the manufactured home, electrical, heating, ventilation, plumbing and air conditioning equipment and other service facilities (including ductwork) are elevated to one (1) foot above the base flood elevation and be securely anchored to an adequately anchored foundation system to resist flotation, collapse and lateral movement.

Sec. 16-11-230(5)1 standards

All recreational vehicles placed on sites within Zones A1—A30, AH and AE on the community's FIRM either: (i) be on the site for fewer than one hundred eighty (180) consecutive days and be fully licensed and ready for highway use; or (ii) meet the permit requirements ...

Sec. 16-11-3302 standards

must have the lowest floor ... elevated above the highest adjacent grade at least one (1) foot above the depth number specified in feet on the community's FIRM (at least three [3] feet if no depth number is specified).

Sec. 16-11-3401 standards

Encroachments are prohibited, including fill, new construction, substantial improvements and other development within the adopted regulatory floodway, unless it has been demonstrated ... that the proposed encroachment would not result in any increase in flood levels ...

Sec. 16-11-3601 standards

must be elevated to one (1) foot above the base flood elevation that existed prior to the placement of fill.

Sec. 16-11-3702 standards

All subdivision proposals including the placement of manufactured home parks and subdivisions shall be reasonably safe from flooding.

Source documents

The chapters of the adopted code that were retrieved, read and extracted from. Everything above traces back to one of these.