Paso Robles, California · General provision

21.56.040

Extracted standards

8 individual requirements pulled out of this section’s prose, each with the sentence it came from.

Other

  • Incorporate compost at a rate of at least four cubic yards per one thousand square feet to a depth of six inches

  • Maximum evapotranspiration adjustment factor for nonresidential0.45 ratio

    and 0.45 for nonresidential projects.

  • Maximum evapotranspiration adjustment factor for residential0.55 ratio

    The evapotranspiration adjustment factor (ETAF) calculated in the Water Efficient Landscape Worksheet shall not exceed 0.55 for residential projects

  • Minimum irrigation efficiency for drip systems81 pct

    and eighty-one percent for drip systems.

  • Minimum irrigation efficiency for overhead spray75 pct

    Irrigation systems shall be designed and constructed to achieve a minimum efficiency of seventy-five percent for overhead spray devices

  • Minimum mulch depth3 inches

    Apply a minimum three-inch layer of mulch on all exposed soil surface of planting areas.

  • Prohibit overhead spray within 24 inches of non-permeable surfaces24 inches

    Prohibit overhead spray irrigation within twenty-four inches of non-permeable surfaces

  • Prohibit turf on slopes greater than 20% adjacent to hardscape20 pct

    Prohibit turf on slopes greater than twenty percent where the toe of the slope is adjacent to an impermeable hardscape.

From the ordinance

The evapotranspiration adjustment factor (ETAF) calculated in the Water Efficient Landscape Worksheet shall not exceed 0.55 for residential projects and 0.45 for nonresidential projects. ... Incorporate compost at a rate of at least four cubic yards per one thousand square feet ... Apply a minimum three-inch layer of mulch on all exposed soil surface of planting areas.
21.56.040