Orange County Unincorporated, California · General provision

Sec. 7-9-108

Dimensional standards

lot requirementsSTREETMIN LOT AREA1 acMAX HEIGHT80 ft
Plan view of the district’s stated lot requirements. Solid line: the property line. Dashed: the setback lines the ordinance imposes; a building must stay inside the tinted envelope. Drawn from the figures extracted below — illustrative, not a survey.

Extracted standards

10 individual requirements pulled out of this section’s prose, each with the sentence it came from.

Other

  • Minimum distance between ground and turbine blade15 ft

    The minimum distance between the ground and any part of the turbine blade shall be fifteen (15) feet.

  • No climbing apparatus within first 12 feet12 ft

    Tower structure shall not have any climbing apparatus within the first twelve (12) feet from the ground.

  • Landscaping shall be provided to screen accessory structures from roads and adjacent residences in compliance with section 7-9-71.

  • Tower structure lighting shall be prohibited unless required by the FAA, FCC or building code.

  • Maximum tower height shall be eighty (80) feet unless applicant can demonstrate special circumstances that require a tower up to one hundred (100) feet.

  • Comply with Noise Control regulations

    The applicant shall demonstrate that the system shall be operated in such a manner as to comply with the requirements set forth in Title 4, Division 6 of the Codified Ordinances of the County of Orange, entitled 'Noise Control.'

  • Removal if inoperable for more than 12 months12 months

    System shall be removed if inoperable for more than twelve (12) consecutive months.

  • Minimum setback for the system shall be at least two (2) times the height of the system from any property line. No part of the system, including guy wire anchors, shall extend closer than thirty (30) feet from any property line.

  • Sign restrictions

    No sign shall be attached to the system, except for signs that identify the manufacturer, installer, or owner of the system; or public health and safety signs. Signs shall be no larger than four (4) square feet.

  • Minimum distance between towers

    Minimum distance between towers shall be at least one and one-half (1.5) times the height of the taller tower.

From the ordinance

Minimum lot size shall be one (1) acre. Maximum tower height shall be eighty (80) feet. Setback at least two times height from property line. No part closer than 30 feet.
Sec. 7-9-108