Sec. 7-9-72.3
Extracted standards
8 individual requirements pulled out of this section’s prose, each with the sentence it came from.
Other
- Maximum ground-mounted solar collector heightMaximum heightThe tallest a building may be, given in feet, in storeys, or both — whichever binds first. abutting residential15 ft
The maximum height of a ground-mounted solar energy collector system shall be fifteen (15) feet when located on a non-residential property abutting a residential zone.
- Maximum ground-mounted solar collector heightMaximum heightThe tallest a building may be, given in feet, in storeys, or both — whichever binds first. in residential districts12 ft
In residential districts, the height of a ground-mounted solar energy collector system shall not exceed twelve (12) feet unless within three (3) feet of the property line, where the maximum height shall be eight (8) feet.
- Maximum ground-mounted solar collector heightMaximum heightThe tallest a building may be, given in feet, in storeys, or both — whichever binds first. near property line8 ft
unless within three (3) feet of the property line, where the maximum height shall be eight (8) feet.
- Maximum ground-mounted solar collector heightMaximum heightThe tallest a building may be, given in feet, in storeys, or both — whichever binds first. in nonresidential districts25 ft
The maximum height shall be twenty-five (25) feet when located on a non-residential property not abutting a residential zone.
- Maximum projection into setbackSetbackThe distance a building must be held back from a lot line. for low solar collectors2 ft
Installations less than six (6) feet in height may project up to two (2) feet into a required setback.
- Maximum roof-mounted photovoltaic heightMaximum heightThe tallest a building may be, given in feet, in storeys, or both — whichever binds first. above limit5 ft
Photovoltaic solar energy systems on the roof may extend up to five (5) feet above the height limit in the district in which it is located or the roof surface on which they are installed.
- Maximum roof-mounted solar water heating heightMaximum heightThe tallest a building may be, given in feet, in storeys, or both — whichever binds first. above limit7 ft
Solar water or swimming pool heating systems may extend up to seven (7) feet above the height limit in the district in which it is located or the roof surface on which they are installed.
- Minimum setbackSetbackThe distance a building must be held back from a lot line. for ground-mounted solar collectors8 ft
Installations six (6) feet or more in height shall be setback a minimum of eight (8) feet from all property lines.
From the ordinance
Ground-mounted solar energy collectors are permitted in all zoning districts. In residential districts, solar energy collectors and their mounting framework shall not be located, installed, and maintained within the front setback and shall not to be visible from the public right-of-way adjacent to the front, side, or rear property line.