Needles, California · General provision

99.10.01

Dimensional standards

Extracted standards

5 individual requirements pulled out of this section’s prose, each with the sentence it came from.

Noise

  • Acoustical analysis required within 60 dB CNEL contour60 dB

    For any residential development within a sixty (60) decibel CNEL contour, an analysis by a professional architect, engineer or building designer shall demonstrate that the required noise levels will be achieved.

  • Acoustical analysis required within 65 dB CNEL contour65 dB

    For any residential development within a sixty-five (65) decibel CNEL contour, an analysis by a professional mechanical or acoustical engineer shall demonstrate that the required noise levels will be achieved.

  • Maximum indoor community noise equivalent level45 dB

    Within each main building, a community noise equivalent level (CNEL) not exceeding forty-five (45) decibels.

  • Maximum outdoor community noise equivalent level65 dB

    In outdoor areas, a community noise equivalent level (CNEL) not exceeding sixty-five (65) decibels...

  • the development shall be designed to provide the lowest noise level reasonably possible within private open areas and/or common usable open areas of at least one hundred (100) square feet per unit

From the ordinance

For all dwellings and group quarters, the development shall be designed to achieve: Within each main building, a community noise equivalent level (CNEL) not exceeding forty-five (45) decibels. In outdoor areas, a community noise equivalent level (CNEL) not exceeding sixty-five (65) decibels...
99.10.01