Napa County Unincorporated, California · General provision

Chapter 18.119, Sections 18.119.040, 18.119.050, 18.119.110, 18.119.120, 18.119.130, 18.119.150, 18.119.170, 18.119.180

Dimensional standards

Extracted standards

15 individual requirements pulled out of this section’s prose, each with the sentence it came from.

Environmental

  • Protection of rare, threatened, or endangered species

    No telecommunications facility or related improvements shall be sited so as to create a significant threat to the health or survival of plant or animal species identified in the Napa County Environmental Resource Mapping System as rare, threatened, or endangered.

Height

Lighting

  • Lighting restrictions

    All telecommunication facilities shall be unlit except for a manually-operated or motion-detector controlled light above the equipment shed door and minimum FAA required tower lighting.

Noise

  • Construction hours

    Outdoor noise producing construction activities shall only take place on weekdays (Monday through Friday) between the hours of seven-thirty a.m. and five-thirty p.m.

  • Backup generator testing hours

    Backup generators shall only be operated during power outages and for testing and maintenance purposes. Testing and maintenance shall only take place on weekdays between the hours of eight-thirty a.m. and four-thirty p.m.

Other

  • Airport safety zone restriction

    No telecommunication facility shall be installed within the safety zone of any airport unless the airport operator indicates that it will not adversely affect the operation of the airport.

  • Graveled area width around structures10 ft

    Graveled areas at least ten feet wide shall be installed completely around all new structures including telecommunication towers.

  • Guy wire anchors shall be set back at least twenty feet from any property line.

  • Maximum access road width8 ft

    Access roads shall be limited to eight feet in width.

  • NIER exposure standard

    No telecommunication facility or combination of facilities shall produce at any time power densities in any inhabited area that exceed the ANSI C95.1-1992 standard for human exposure.

  • Ridgeline and scenic area restriction

    No telecommunication facility shall be installed on an exposed ridgeline, in or at a location readily visible from a public trail, public park or other outdoor recreation area, or in a scenic area identified in the Napa County Environmental Resource Mapping System unless it blends with the surrounding environment.

  • Tower setbackSetbackThe distance a building must be held back from a lot line. from public trail, park, or outdoor recreation area100 ft

    at least one hundred feet from any public trail, park, or outdoor recreation area.

  • Telecommunication towers shall be set back at least twenty percent of the tower height from all property lines.

Parking

Signage

  • Facility identification sign size512 sqin

    A permanent, weather-proof, approximately sixteen- by thirty-two-inch facility identification sign

From the ordinance

Telecommunication towers shall be set back at least twenty percent of the tower height from all property lines... In no instance shall the height of a telecommunication tower exceed one hundred fifty feet.