Chapter 20.170 - Moveable Tiny Homes
Dimensional standards
Extracted standards
18 individual requirements pulled out of this section’s prose, each with the sentence it came from.
Design
- Skirting required
The undercarriage, including wheels and axles, shall be hidden from view with a solid wood, metal, or concrete apron.
Height
- Maximum heightMaximum heightThe tallest a building may be, given in feet, in storeys, or both — whichever binds first. when towed14 ft
maximum height of fourteen (14) feet when being towed
Other
- Allowed uses
Moveable Tiny Homes may be established as a single-family dwelling, accessory dwelling unit and/or second residential unit
- Compliance with ANSI 119.5 or NFPA 1192
Moveable Tiny Homes shall meet either the provisions of ANSI 119.5 or NFPA 1192.
- DMV registration required
Moveable Tiny Homes shall be licensed and registered with the California Department of Motor Vehicles.
- Double pane windows required
Windows shall be double pane glass or better
- Efficiency kitchen required
A Moveable Tiny Home shall include at minimum an efficiency kitchen
- Fire inspection frequency5 years
require an inspection... every five (5) years
- Generators prohibitedProhibitedNot allowed in the district at all, short of rezoning or a variance. except emergencies
Generators are prohibited except when needed in emergencies.
- GFI shutoff breaker required
All Moveable Tiny Homes shall have a GFI shutoff breaker.
- Maximum size400 sqftsq ftSquare feet. An acre is 43,560 sq ft; a typical suburban lot is 7,000–10,000.
Maximum size: four hundred (400) gross square feet.
- Minimum insulation R-value ceiling19 R
R-19 in ceiling
- Minimum insulation R-value walls and floors13 R
Insulation standards shall be a minimum of R-13 in walls and floors
- Minimum size150 sqftsq ftSquare feet. An acre is 43,560 sq ft; a typical suburban lot is 7,000–10,000.
Minimum size: one hundred fifty (150) gross square feet.
- Approved parking pad required
An approved designated parking area of compacted all weather surface including bumper guards, curbs or other installations to prevent movement of the unit.
- Third-party inspection required
All units must be inspected and certified for compliance... by a qualified third-party inspector
- Wall stud spacing24 in
Wall framing studs shall be sixteen (16) to twenty-four (24) on center
- Water and waste connection required
A Moveable Tiny Home shall be connected to an approved water source and waste disposal system
From the ordinance
Moveable Tiny Homes may be established as a single-family dwelling, accessory dwelling unit and/or second residential unit in all zoning districts that allow residential dwellings and/or accessory uses, subject to the limitations contained in this Chapter.