Dimensional standards
Servicing
- Applies near
- Urban Residential zones
- Applies within
- 25 ft
- Geographic extent
- Within 25 feet of a lot line abutting a site zoned Urban Residential (RR-2.5, RR-1, SRR, R-7,000, R-10,000, or R-15,000)
Extracted standards
3 individual requirements pulled out of this section’s prose, each with the sentence it came from.
Fencing & walls
- Perimeter masonry wall6 ft
A masonry wall or fence (wrought iron/tubular steel) of not less than 5 nor greater than 6 feet in height shall be provided at the property line around residential subdivisions and multi-dwelling (>5 units) or mixed-use sites, with exceptions.
Other
- Step-down heightMaximum heightThe tallest a building may be, given in feet, in storeys, or both — whichever binds first. near Urban Residential35 ft
On the portion of a site within 25 feet of a lot line abutting a site zoned Urban Residential, the maximum allowed step-down height shall be 35 feet.
- Window privacy
New windows above first story within 20 feet of existing residential windows must use opaque/clerestory glass or be located at least 5 feet above finished floor.
From the ordinance
The heights of structures at the edge of multi-unit residential and mixed-use developments shall be 'stepped down' to match or complement the maximum height of buildings allowed on any abutting property zoned Rural Residential and Urban Residential.