Lancaster, California · General provision

17.40.390

Heavy IndustrialAll Lancaster districts0

Dimensional standards

lot requirementsSTREETSTREETbuildable areaFront 20 ftStreet side 20 ft
Plan view of the district’s stated lot requirements. Solid line: the property line. Dashed: the setback lines the ordinance imposes; a building must stay inside the tinted envelope. Drawn from the figures extracted below — illustrative, not a survey.

Uses

Conditional / special use1

Extracted standards

13 individual requirements pulled out of this section’s prose, each with the sentence it came from.

Floodplain

Other

  • Drinking water supply protection

    All facilities shall locate in areas posing minimal threats to the contamination of drinking water supplies contained in reservoirs and aqueducts.

  • Emergency response access

    All facilities shall locate in areas where fire departments are able to quickly respond to hazardous materials accidents and where demonstrated emergency response times are deemed acceptable by the local fire department official.

  • Geologic hazard avoidance

    All facilities shall avoid locating in areas of potential rapid geologic change, or areas with high rate of subsidence and areas subject to liquefaction unless containment structures are designed, constructed and maintained in a manner acceptable to the director of public works and/or the city engineer so as to preclude failure as a result of such changes.

  • All hazardous waste facilities shall erect a minimum 8-foot high decorative block wall that shall not exceed 15 feet in height.

  • Minimum buffer from residential zones2,000 ft

    No facility shall be permitted within 2,000 feet of residential zoned sites, hospital sites, school sites or sites planned for immobile populations unless the applicant proves through a risk analysis that a 2,000 foot buffer zone is not required to protect public health and safety.

  • Minimum distance from active fault200 ft

    No facility shall be placed within 200 feet of any known active earthquake fault or lineation suggesting the presence of a fault.

  • All hazardous waste facilities shall erect a minimum 8-foot high decorative block wall that shall not exceed 15 feet in height.

  • Minimum distance from water features500 ft

    No facility shall be placed within 500 feet of a dry wash or river, aqueduct, reservoir, supply well, or aquifer recharge area unless design features are incorporated to avoid any potential for water contamination.

  • All facilities shall be prohibited in areas of recreation, cultural or aesthetic value, as determined by the director.

  • Adequate sewer capacity required

    Facilities generating wastewater shall be located in areas with adequate sewer capacity and treatment capability to accommodate the expected wastewater discharge.

  • Transportation routes

    All facilities shall be located so that distance traveled on city streets is kept to a minimum, and any routes to and from state or interstate highways to or from the facility are used primarily by trucks, and the number of nonindustrial structures along such routes is minimal.

  • The wall shall be set back at least 20 feet from the property line when located on street or highway frontage.

From the ordinance

Facilities shall be located in areas designated on the general plan land use map as heavy industrial, and shall only be permitted in the HI zone.
17.40.390