17.12.040, 17.12.050, 17.12.130
Dimensional standards
Uses
Permitted by right15
- Access for a Purpose Not Permitted in the Subject Zone
- Agriculture - Crops, Fields
- Consignment Store, Pawnshop, Secondhand Store, Surplus Store
- Day Care Center
- Eating and Drinking Establishments
- Financial Institutions and Services
- Offices—Business, Government or Professional
- Public Safety Facilities and Services
- Rental Establishments
- Repair Services
- Schools - Business and Professional
- Schools - Small Specialty/Charter
- Services - Commercial
- Services - Office Professional
- Tattoo Parlors and Body Piercing Establishments
Conditional / special use4
Accessory9
- Accessory buildings and structures
- Automobile body and fender repair (incidental to sale of new automobiles)
- Minor repair of boats (incidental to sale of boats)
- Day nursery for children (employer-provided)
- Manufacturing, processing, packaging, treating and storage (incidental to business)
- Rental, leasing or repair of articles sold on premises
- Electric Vehicle Charging Station
- Mini Wireless Telecommunication Facilities
- Collection bins
Extracted standards
24 individual requirements pulled out of this section’s prose, each with the sentence it came from.
Fencing & walls
- Maximum fence heightMaximum heightThe tallest a building may be, given in feet, in storeys, or both — whichever binds first. in front yardYardThe open space left between a building and its lot line — the space a setback creates.6 ft
Fences and walls within a required front yard shall not exceed a height of 6 feet.
- Maximum fence heightMaximum heightThe tallest a building may be, given in feet, in storeys, or both — whichever binds first. in corner side, interior side, and rear yards6 ft
Fences and walls within a required corner side, interior side, and/or rear yard shall not exceed 6 feet.
- Maximum fence heightMaximum heightThe tallest a building may be, given in feet, in storeys, or both — whichever binds first. with director approval8 ft
Director may permit fences or walls within any required yard to a height not to exceed 8 feet, subject to materials requirements.
- Maximum retaining wall heightMaximum heightThe tallest a building may be, given in feet, in storeys, or both — whichever binds first.6 ft
Retaining walls not to exceed 6 feet in height are permitted in all yards.
Other
- Maximum cargo container heightMaximum heightThe tallest a building may be, given in feet, in storeys, or both — whichever binds first.8.5 ft
Cargo containers used for temporary construction storage shall not exceed eight feet in width, eight feet six inches in height, and 40 feet in length.
- Maximum cargo container length40 ft
Cargo containers used for temporary construction storage shall not exceed eight feet in width, eight feet six inches in height, and 40 feet in length.
- Maximum cargo container width8 ft
Cargo containers used for temporary construction storage shall not exceed eight feet in width, eight feet six inches in height, and 40 feet in length.
- Cargo container setbackSetbackThe distance a building must be held back from a lot line. from property line5 ft
Cargo containers shall be set back a minimum of five feet from any property line and a minimum of 10 feet from any structure.
- Cargo container setbackSetbackThe distance a building must be held back from a lot line. from structure10 ft
Cargo containers shall be set back a minimum of five feet from any property line and a minimum of 10 feet from any structure.
- Christmas tree sale period
Christmas trees and wreaths: seasonal sale between Nov 1 and Dec 25, removal by Dec 31.
- Maximum emergency storage duration15 days
Emergency storage: cargo containers for emergency storage, max 15 days, extendable 10 days, require container permit.
- Maximum number of employees in accessoryAccessory useA secondary activity customarily incidental to the main use of the lot — a garage, a home office. manufacturing5 count
Manufacturing, processing, packaging, treating and storage related to business: restricted to ground floor, not more than 25% of ground floor area, not more than 5 employees, not nearer than 50 feet to any residential zone.
- Maximum manufacturing ground floor area percentage25 pct
Manufacturing, processing, packaging, treating and storage related to business: restricted to ground floor, not more than 25% of ground floor area, not more than 5 employees, not nearer than 50 feet to any residential zone.
- Minimum distance from accessoryAccessory useA secondary activity customarily incidental to the main use of the lot — a garage, a home office. manufacturing to residential zone50 ft
Manufacturing, processing, packaging, treating and storage related to business: restricted to ground floor, not more than 25% of ground floor area, not more than 5 employees, not nearer than 50 feet to any residential zone.
- Maximum outdoor sales days per year12 days
Outdoor sales and promotional activities: max 12 days per year between Jan 15 and Nov 15, no more than 10% of parking spaces, clear aisle 5 ft.
- Maximum parking spaces used for outdoor sales10 pct
Outdoor sales and promotional activities: max 12 days per year between Jan 15 and Nov 15, no more than 10% of parking spaces, clear aisle 5 ft.
- Minimum clear aisle width for outdoor sales5 ft
Outdoor sales and promotional activities: max 12 days per year between Jan 15 and Nov 15, no more than 10% of parking spaces, clear aisle 5 ft.
- Pumpkin sale period
Pumpkins and other seasonal agricultural products: sale from Oct 1 through Thanksgiving, removal within 7 days.
- Maximum relocation storage duration15 days
Relocation storage: cargo containers for relocation, max 15 days, extendable 10 days, require container permit, may use up to 10% of parking spaces.
- Maximum storage container use duration3 months
Storage containers for merchandise during holidays: placement within loading areas or nonessential parking, not exceed 3 months.
- Temporary construction storage removal after permit expiration30 days
Temporary construction or commercial storage: storage of building materials, machinery, equipment with active building permit, removal within 30 days after permit expiration.
- Temporary office removal after permit expiration30 days
Temporary offices: placement with active building permit, removal within 30 days after permit expiration.
Signage
- Maximum EVCS sign area4 sqftsq ftSquare feet. An acre is 43,560 sq ft; a typical suburban lot is 7,000–10,000.
One standard nonilluminated sign, not to exceed 4 square feet in area and 10 feet in height, may be posted for the purpose of identifying the location of each cluster of EVCSs.
- Maximum EVCS sign heightMaximum heightThe tallest a building may be, given in feet, in storeys, or both — whichever binds first.10 ft
One standard nonilluminated sign, not to exceed 4 square feet in area and 10 feet in height, may be posted for the purpose of identifying the location of each cluster of EVCSs.
From the ordinance
Fences and walls within a required front yard shall not exceed a height of 6 feet.