Other

  • Maximum street-facing facade width70 ft

    Street-facing façades may not exceed 70 feet in width.

  • Maximum street-facing wall length before articulation50 ft

    Street-facing façades greater than 50 feet in length must be articulated with bays, projections, recesses or other design elements that effectively break-up the mass of the building.

  • Maximum units in multiplex5 count

    Each multiplex must consist of 3-5 dwelling units

  • Minimum porch depth6 ft

    each dwelling unit shall have a primary entrance denoted by a porch or covered entry that is at least eight feet in width and six feet in depth.

  • Minimum porch width8 ft

    each dwelling unit shall have a primary entrance denoted by a porch or covered entry that is at least eight feet in width and six feet in depth.

  • Minimum units in multiplex3 count

    Each multiplex must consist of 3-5 dwelling units

Parking

  • Parking location

    Outdoor (surface) parking areas shall not be located between the street and principal structures.

From the ordinance

Each multiplex must consist of 3-5 dwelling units and each dwelling unit shall have a primary entrance denoted by a porch or covered entry that is at least eight feet in width and six feet in depth.