Waynesboro, Virginia · General provision

Sec. 98-3.3.5, 98-3.3.6, 98-3.3.7

Dimensional standards

Servicing

Geographic extent
Applies to all lands within the City identified as floodprone, as shown on the Flood Insurance Rate Map.

Uses

Prohibited4

  • solid waste, trash hauling, landfills, dumps, junkyards, storage tanks, hazardous materials storage, outdoor storage of vehicles and/or materials
  • filling of jurisdictional wetlands
  • damming or relocation of any watercourse that will result in any downstream increase in flood levels during the base flood
  • construction or storage of any object subject to flotation or movement during flooding

Extracted standards

19 individual requirements pulled out of this section’s prose, each with the sentence it came from.

Floodplain

  • Electrical control panels above design flood elevation

    Electrical control panels in permitted structures shall be mounted above the design flood elevation.

  • Enclosed areas below flood protection elevation use restriction

    Fully enclosed areas below the regulatory flood protection elevation shall not be designed or used for human habitation, but shall only be used for parking of vehicles, building access, or limited storage of maintenance equipment.

  • Flood resistant materials required

    New construction and substantial improvements shall be constructed with materials and utility equipment resistant to flood damage.

  • Floodproofing certification required

    A qualified engineer or architect shall certify that the floodproofing methods are adequate to withstand the flood depths, pressures, velocities, impact, and uplift forces and other factors associated with the base flood.

  • Within any floodway area, no encroachments, including, but not limited to, fill, new construction, substantial improvements or other development shall be permitted unless the applicant demonstrates, through hydrologic and hydraulic analyses, that the proposed encroachment would result in any increase in the 100-year flood elevation.

  • The bottom of all openings shall be no higher than one foot above finished grade.

  • Non-residential lowest floor at or above base flood elevation0 ft

    New construction or substantial improvement of any commercial, industrial, or non-residential building (or manufactured home) shall have the lowest floor, including basement, elevated to or above the base flood elevation (recommend > one-foot freeboard).

  • Residential lowest floor at or above base flood elevation0 ft

    New construction or substantial improvement of any residential structure (including manufactured homes) shall have the lowest floor, including basement, elevated to or above the base flood elevation (recommend > one-foot freeboard).

  • Manufactured homes shall be anchored to prevent flotation, collapse, or lateral movement.

  • Foundation vents shall have a minimum of two openings having a total net area of not less than one square inch for every square foot of enclosed area subject to flooding.

  • Minimum lowest floor elevation above design flood elevation1 ft

    All new construction and substantial improvement of structures shall have the lowest floor, including basement, elevated at least one foot above the design flood elevation.

  • Minimum lowest floor elevation for shallow flooding (no depth number)2 ft

    If no flood depth number is specified, the lowest floor, including basement, shall be elevated no less than two feet above the highest adjacent grade.

  • The manufactured home chassis is supported by reinforced piers or other foundation elements of at least an equivalent strength, of no less than 36 inches in height above the grade.

  • Recreational vehicle 180-day limit180 days

    No recreational vehicles may be placed on sites except for non-residential use and then shall either be on the site for fewer than 180 consecutive days, or be fully licensed and ready for highway use.

  • Sanitary sewer systems designed to minimize infiltration

    All new or replacement sanitary sewer facilities and private package sewage treatment plants shall be designed to minimize or eliminate infiltration of floodwaters into the systems.

  • Storm drainage design requirements

    All storm drainage facilities shall be designed to convey the flow of surface waters without damage to persons or property.

  • Streets and sidewalks design to minimize flood flow

    Streets and sidewalks should be designed to minimize their potential for increasing and aggravating the levels of flood flow.

  • Utilities elevated to minimize impairment

    All utilities, such as gas lines, electrical and telephone systems being placed in floodprone areas should be located, elevated, where possible, and constructed to minimize the chance of impairment during a flooding occurrence.

  • Water systems designed to minimize infiltration

    All new or replacement water facilities shall be designed to minimize or eliminate infiltration of floodwaters into the system.

From the ordinance

No land shall be developed and no structure shall be located, relocated, constructed, reconstructed, enlarged or structurally altered in the -FO district except in full compliance with the terms and provisions of this section and any other applicable ordinances and regulations which apply to uses within the jurisdiction of this section.
Sec. 98-3.3.5, 98-3.3.6, 98-3.3.7