§ 180-43.1
Dimensional standards
Lot
Extracted standards
8 individual requirements pulled out of this section’s prose, each with the sentence it came from.
Other
- Maximum operations per year3 operations
No more than three confined feeding operations, as defined in this section, built on a parcel or adjoining parcels under a single ownership, shall be constructed within a period of one year.
- Minimum lot areaMinimum lot areaThe smallest parcel on which the district allows anything to be built.10 acresacre43,560 square feet — about the size of an American football field without the end zones.
All confined feeding operations shall be built on a parcel or adjoining and contiguous parcels of 10 acres or more under a single ownership.
- Min setbackSetbackThe distance a building must be held back from a lot line. from adjacent property100 ft
One hundred feet to any adjacent property where existing agricultural operations are being pursued.
- Min setbackSetbackThe distance a building must be held back from a lot line. from residence600 ft
Six hundred feet to any structure designed to be occupied as a residence
- Min setbackSetbackThe distance a building must be held back from a lot line. from residential districtZoning districtA mapped area with one set of rules, identified by a code like R-1 or B-2./school/churchReligious facilityA building used for organised worship, often with halls and schools attached.600 ft
Six hundred feet to any residential zoning district, school, church, community center or commercial business establishment
- Min setbackSetbackThe distance a building must be held back from a lot line. from road200 ft
Two hundred feet to any primary highway, secondary highway, roadway or other right-of-way for passage.
- Min setbackSetbackThe distance a building must be held back from a lot line. from town boundary1,000 ft
One thousand feet to any boundary of a town within the County.
- Min setbackSetbackThe distance a building must be held back from a lot line. from water source300 ft
Three hundred feet to any recreational pond, lake, river, creek, spring, reservoir or any public or private water supply system
From the ordinance
All confined feeding operations shall be built on a parcel or adjoining and contiguous parcels of 10 acres or more under a single ownership.