Warren County Unincorporated, Virginia · General provision

§ 180-16K(2)

Dimensional standards

Servicing

Geographic extent
All Special Flood Hazard Areas (SFHA) as shown on the Flood Insurance Rate Map (FIRM) and Digital Flood Insurance Rate Map (DFIRM)

Extracted standards

37 individual requirements pulled out of this section’s prose, each with the sentence it came from.

Accessory structures

Environmental

  • Protection of threatened and endangered species

    Development within the special flood hazard areas shall not adversely impact any threatened and endangered special status faunal species as identified by the Virginia Department of Wildlife Resources (DWR).

Floodplain

  • Alteration of compliant buildings

    Any alteration, repair, reconstruction or improvements to a building that is in compliance with the provisions of this section shall meet the requirements of new construction as contained in this section.

  • Anchoring to prevent flotation

    New construction and substantial improvements shall be built according to this section and the VA USBC, and anchored to prevent flotation, collapse or lateral movement of the structure.

  • The building of critical facilities in the special flood hazard area 1% annual chance and 0.2% annual chance flood/shaded zone X area shall be prohibited.

  • Flood-damage-resistant materials

    New construction and substantial improvements shall be constructed with materials and utility equipment resistant to flood damage.

  • Hydrologic and hydraulic analysis may be required

    In any flood zone the Floodplain Administrator may require a hydrologic and hydraulic analysis for any development.

  • Manufactured homes shall be anchored to prevent flotation, collapse or lateral movement. Methods of anchoring may include, but are not limited to, use of over-the-top or frame ties to ground anchors.

  • Methods to minimize flood damage

    New construction or substantial improvements shall be constructed by methods and practices that minimize flood damage.

  • Alteration of noncompliant buildings

    Any alteration, repair, reconstruction or improvements to a building that is not in compliance with the provisions of this section shall be undertaken only if said nonconformity is not furthered, extended or replaced.

  • Nonresidential lowest floor elevation2.5 ft

    Substantial improvement of any existing commercial, industrial, or institutional buildings located in all A and AE Zones shall have the lowest floor, including basement, elevated to no lower than 2 1/2 feet (30" above BFE) above the base flood elevation.

  • Nonresidential floodproofing alternative

    These buildings may be floodproofed in lieu of being elevated, provided that all areas of the building components below the elevation corresponding to the BFE plus 2 1/2 feet (30" above BFE) are watertight with walls substantially impermeable to the passage of water, and use structural components having the capability of resisting hydrostatic and hydrodynamic loads and the effect of buoyancy.

  • Residential lowest floor elevation2.5 ft

    Within the Special Flood Hazard Areas Zones A and AE, new construction or substantial improvement of any residential structure (including manufactured homes) shall have the lowest floor, including basement, elevated no lower than 2 1/2 feet (30" above BFE) above the base flood elevation.

  • Sanitary sewage system design

    New and replacement sanitary sewage systems shall be designed to minimize or eliminate infiltration of floodwaters into the systems and discharges from the systems into floodwaters.

  • Utility equipment protection

    Electrical, heating, ventilation, plumbing, air-conditioning equipment and other service facilities, including duct work, shall be designed and/or located so as to prevent water from entering or accumulating within the components during conditions of flooding.

  • On-site waste disposal systems

    On-site waste disposal systems shall be located and constructed to avoid impairment to them or contamination from them during flooding.

  • Water supply system design

    New and replacement water supply systems shall be designed to minimize or eliminate infiltration of floodwaters into the system.

Other

  • Enclosed area below flood protection elevation

    Enclosed areas of new construction or substantially improved structures which are below the regulatory flood protection elevation shall not be designed or used for human habitation, but shall only be used for parking of vehicles, building access or limited storage of maintenance equipment.

  • Fence permit required in SFHA

    Prior to installation, any fence located within the special flood hazard area shall first receive a zoning permit, floodplain determination and documentation identifying the fence type and its location to be approved by the Floodplain Administrator or Zoning Administrator.

  • Maintain flood-carrying capacity

    The flood-carrying capacity within an altered or relocated portion of any watercourse shall be maintained. Under no circumstances shall any use, activity, and/or development adversely affect the capacity of the channels or floodways of any watercourse, drainage ditch, or any other drainage facility or system.

  • Flood-resistant materials below elevation

    Be constructed entirely of flood-resistant materials below the regulatory flood protection elevation.

  • Flood vent opening requirement

    Provide a minimum of two openings on different sides of each enclosed area subject to flooding. The total net area of all openings must be at least one square inch for each square foot of enclosed area subject to flooding. The bottom of all required openings shall be no higher than one foot above the adjacent grade.

  • The parking and storage of inoperative major recreational equipment shall be prohibited.

  • All manufactured homes placed or substantially improved in an existing manufactured home park or subdivision must be elevated so that the lowest floor of the manufactured home is elevated no lower than one foot 2 1/2 feet (30" above BFE) above the base flood elevation.

  • The manufactured home chassis is supported by reinforced piers or other foundation elements of at least an equivalent strength and of no less than 36 inches in height above the grade.

  • Recreational vehicle time limit180 days

    All recreational vehicles placed on sites must either be on the site for fewer than 180 consecutive calendar days in any one year and be fully licensed and ready for highway use.

  • Solid panel or board on board/batten fencing shall not be permitted.

  • Subdivision drainage requirement

    All subdivision proposals shall have adequate drainage provided to reduce exposure to flood hazards.

  • Subdivision proposals minimize flood damage

    All subdivision proposals shall be consistent with the need to minimize flood damage.

  • Hydrologic analysis for large subdivisions

    Hydrologic and hydraulic analysis and/or drainage study, erosion and sediment, encroachment analysis and base flood elevation data shall be provided for subdivision proposals and other proposed development proposals (including manufactured home parks and subdivisions greater than 50 lots or five acres) that are in the SFHA or within 100 feet of the boundary of the special flood hazard area.

  • Subdivision utilities flood protection

    All subdivision proposals shall have public utilities and facilities such as sewer, gas, electrical and water systems located and constructed to minimize flood damage.

  • Permit for watercourse alteration

    Prior to any proposed alteration or relocation of any channels or of any watercourse, stream, etc., within this jurisdiction a permit shall be obtained from the United States Corps of Engineers (USACE), the Virginia Department of Environmental Quality (DEQ) and the Virginia Marine Resources Commission (VMRC).

Setback

From the ordinance

In all SFHA Districts the following provisions shall apply to all permits: The building of critical facilities in the special flood hazard area 1% annual chance and 0.2% annual chance flood/shaded zone X area shall be prohibited.
§ 180-16K(2)