Warren County Unincorporated, Virginia · General provision
§ 180-16K(5)
Dimensional standards
Servicing
- Geographic extent
- Areas identified as AE Zone on the Flood Insurance Rate Maps accompanying the Flood Insurance Study
Uses
Permitted by right2
- residential structures
- nonresidential commercial, industrial and institutional structures
Prohibited1
Extracted standards
2 individual requirements pulled out of this section’s prose, each with the sentence it came from.
Other
- Minimum lowest floor elevation above BFE2.5 ft
lowest floor, including basement, elevated no lower than 2 1/2 feet (30" above BFE) above the base flood elevation
Setback
- SetbackSetbackThe distance a building must be held back from a lot line. from edge of regulatory floodway50 ft
meet a linear setback of 50 feet from the edge of the regulatory floodway
From the ordinance
Any new construction or substantial improvement of any residential structure (including manufactured homes) shall have the lowest floor, including basement, elevated no lower than 2 1/2 feet above the base flood elevation (30" above BFE). Any new construction or development must meet a linear setback of 50 feet from the edge of the regulatory floodway.