Virginia Beach, Virginia · General provision

Sec. 209

Dimensional standards

lot requirementsSTREETMIN LOT AREA40,000 sq ft
Plan view of the district’s stated lot requirements. Solid line: the property line. Dashed: the setback lines the ordinance imposes; a building must stay inside the tinted envelope. Drawn from the figures extracted below — illustrative, not a survey.

Uses

Conditional / special use1

Extracted standards

12 individual requirements pulled out of this section’s prose, each with the sentence it came from.

Other

  • Nonreflective matte finish required

    All portions of a wind energy conversion system shall be of a nonreflective white, black, galvanized steel, aluminum or other matte-finish color designed to blend with the surrounding environment.

  • Redundant braking system required

    All systems shall be equipped with a redundant braking system that engages at wind speeds in accordance with the manufacturer's specifications so as to minimize the potential for wind damage to the system or its supporting structure.

  • Electrical connections underground or hidden

    All electrical controls, control wiring and power lines shall be located underground or otherwise hidden from view.

  • No illumination unless required by FAA

    No portion of a system shall be illuminated unless required by the Federal Aviation Administration.

  • For freestanding wind energy conversion systems outside of residential districts, forty thousand (40,000) square feet plus an additional twenty thousand (20,000) square feet for each such system in excess of one (1).

  • Minimum rotor clearance for horizontal-axis turbines25 ft

    The minimum rotor clearance of freestanding wind energy conversion systems shall be twenty-five (25) feet above ground level for systems incorporating horizontal-axis turbines and ten (10) feet for systems incorporating vertical-axis turbines.

  • Minimum rotor clearance for vertical-axis turbines10 ft

    The minimum rotor clearance of freestanding wind energy conversion systems shall be twenty-five (25) feet above ground level for systems incorporating horizontal-axis turbines and ten (10) feet for systems incorporating vertical-axis turbines.

  • Maximum noise level at property line55 dBA

    The highest level of noise generated by the system, as measured at any adjoining property line, shall not exceed an A-weighted decibel level of 55 dB(A).

  • Maximum projection above roofline for roof-mounted systems8 ft

    Roof-mounted wind energy conversion systems may project a maximum of eight (8) feet above the roofline of the structure on which they are located unless a greater height is allowed by the conditional use permit.

  • No tower in any freestanding wind energy conversion system shall be located closer to any property line or public right-of-way than a distance equal to one hundred ten (110) percent of the height of the tower or the setback specified in the applicable district regulations, whichever is greater.

  • No signage except safety and warning signs

    No signage, other than safety and warning signs, shall be allowed.

  • Monopole construction required

    All freestanding towers shall be of monopole construction, without guy wires or visible anchors, unless allowed by the conditional use permit.

From the ordinance

Wind energy conversion systems shall be subject to the following requirements:
Sec. 209