Sec. 58-657 (Code 1996, § 114-74)
Dimensional standards
Lot
Uses
Permitted by right1
Extracted standards
7 individual requirements pulled out of this section’s prose, each with the sentence it came from.
Other
- Landscaped buffer width25 ft
A landscaped buffer area of not less than 25 feet in width shall be provided adjacent to all boundaries of a manufactured home park.
- Minimum front yardYardThe open space left between a building and its lot line — the space a setback creates. from interior roadway20 ft
No manufactured home, accessory structure or other building or structure within a manufactured home park shall be located within 20 feet of an interior roadway.
- Minimum recreation area10 pct
Areas for recreation shall in the aggregate consist of not less than ten percent of the gross area of the manufactured home park.
- Minimum separation between manufactured homesManufactured homeA dwelling built in a factory to a federal standard and transported to the site.30 ft
No manufactured home shall be located within 30 feet of any other manufactured home.
- Minimum setbackSetbackThe distance a building must be held back from a lot line. from space boundary10 ft
No manufactured home or other building or structure shall be located within ten feet of a boundary of a manufactured home space.
- Minimum street frontageFrontageThe length of a lot line that touches a public street. for park200 ft
Every manufactured home park shall have not less than 200 feet of frontage on an improved public street.
- Underground utilities required
All utilities within a manufactured home park shall be installed underground.
From the ordinance
Minimum dimensions of manufactured home space: 50 feet in width and 100 feet in length. No manufactured home within 10 feet of space boundary, 25 feet of public street ROW.