Lighting

  • Building-mounted light below roof line

    Any building-mounted light shall be mounted below the roof line.

  • Full shielding

    All outdoor lighting shall be fully shielded or located, aimed, and shielded so as not to present glare on abutting lots or streets and to minimize spill light trespassing upward or across lot lines.

  • House shield required within 30 ft of residential lot30 ft

    provided that any lighting fixture within thirty (30) feet of an abutting lot line of a residentially zoned property is equipped with a house shield which side shields the light fixture on the side of the residentially zoned lot.

  • No direct shine into residential units

    No outdoor lighting shall be permitted which shines directly into abutting residential dwelling units, buildings on adjacent lots, or abutting streets, or for which the point source of illumination (arc tube) is visible at the property line.

  • Pole-mounted lighting distance from lot line in residential districts10 ft

    In all residential districts, the MX, Mixed Use District, and the IN, Institutional District, pole-mounted lighting shall be located no closer than ten (10) feet to any lot line and shall not exceed eighteen (18) feet in height, measured from the lowest light-emitting part of the fixture to the adjacent grade.

  • In all zoning districts, other than those set forth in subsection (A) above, pole-mounted lighting shall not exceed thirty-five (35) feet in height, measured from the lowest light-emitting part of the fixture to the adjacent grade, provided that any lighting fixture within thirty (30) feet of an abutting lot line of a residentially zoned property is equipped with a house shield which side shields the light fixture on the side of the residentially zoned lot.

  • In all residential districts, the MX, Mixed Use District, and the IN, Institutional District, pole-mounted lighting shall be located no closer than ten (10) feet to any lot line and shall not exceed eighteen (18) feet in height, measured from the lowest light-emitting part of the fixture to the adjacent grade.

  • Electrical feeds underground

    Electrical feeds to lighting standards shall run underground, not overhead.

From the ordinance

All outdoor lighting shall be fully shielded or located, aimed, and shielded so as not to present glare on abutting lots or streets... In all residential districts, the MX, Mixed Use District, and the IN, Institutional District, pole-mounted lighting shall be located no closer than ten (10) feet to any lot line and shall not exceed eighteen (18) feet in height...
Sec. 36.2-625