Dimensional standards
Height & bulk
- Minimum landscaping
- 4%
Servicing
- Applies near
- B-1, B-2, B-3, M-1, M-2 districts
- Geographic extent
- Towers and antennas permitted only in B-1, B-2, B-3, M-1, M-2 districts
Extracted standards
7 individual requirements pulled out of this section’s prose, each with the sentence it came from.
Other
- Maximum extension of antenna above existing structure30 ft
The antenna does not extend more than 30 feet above the highest point of the structure
- Maximum heightMaximum heightThe tallest a building may be, given in feet, in storeys, or both — whichever binds first. increase from roof equipment50 pct
and shall not increase the total height of the existing structure by more than 50 percent.
- Maximum roof area occupied by equipment25 pct
If the equipment, storage cabinet or storage structure is located on the roof of a building, it shall not occupy more than 25 percent of the roof area
- HeightMaximum heightThe tallest a building may be, given in feet, in storeys, or both — whichever binds first. of security fencing around towers6 ft
Towers shall be enclosed by security fencing not less than six feet in height
- Maximum heightMaximum heightThe tallest a building may be, given in feet, in storeys, or both — whichever binds first. increase for co-location30 ft
An existing tower may be modified or rebuilt to a taller height, not to exceed 30 feet over the tower's original height, to accommodate the co-location of an additional antenna.
- Width of landscaped buffer around tower compound4 ft
The standard buffer shall consist of a landscaped strip at least four feet wide outside the perimeter of the tower compound.
- Tower setbackSetbackThe distance a building must be held back from a lot line. from lot lines as percentage of heightMaximum heightThe tallest a building may be, given in feet, in storeys, or both — whichever binds first.100 pct
Towers must be set back a distance equal to at least 100 percent of the height of the tower from any adjoining lot line or line of any public utility easement.
From the ordinance
Towers must be set back a distance equal to at least 100 percent of the height of the tower from any adjoining lot line... Towers shall be enclosed by security fencing not less than six feet in height...