Purcellville, Virginia · General provision

Sec. 3.4(17)

Dimensional standards

lot requirementsSTREETFront 15 ftRear 25 ftSide 10 ftMin width 20 ftMIN LOT AREA2,000 sq ftMAX HEIGHT35 ftMAX LOT COVERAGE40%MAX DENSITY8 du/acMIN UNIT SIZE1,200 sq ft
Plan view of the district’s stated lot requirements. Solid line: the property line. Dashed: the setback lines the ordinance imposes; a building must stay inside the tinted envelope. Drawn from the figures extracted below — illustrative, not a survey.

Uses

Extracted standards

9 individual requirements pulled out of this section’s prose, each with the sentence it came from.

Density

Height

Other

Setback

From the ordinance

The minimum project area shall be two acres. A maximum density of eight units per gross acre, excluding floodplain and slopes exceeding 25 percent, shall be permitted. A minimum of six dwellings are required for each development. The minimum lot area per dwelling unit shall be 2,000 square feet. The minimum lot width shall be 20 feet for interior lots and 30 feet for end and corner lots. The minimum front yard per dwelling unit shall be 15 feet. The minimum rear yard shall be 25 feet. The minimum side yard for end and corner lots shall be ten feet. Every dwelling unit shall have a minimum gross floor area of 1,200 square feet. Maximum building height for townhouses shall be 35 feet. The maximum lot coverage shall be 40 percent.