Dimensional standards
Servicing
- Geographic extent
- Citywide loading standards
Extracted standards
5 individual requirements pulled out of this section’s prose, each with the sentence it came from.
Other
- Loading area paving requirement
The ground surface of loading areas shall be paved with a durable, dust free and hard material, such as bituminous hot mix or Portland cement, concrete, or some comparable material.
- Minimum loading aisle width22 ft
a minimum aisle width of 22 feet
- Minimum overhead clearance14 ft
with at least 14 feet of overhead clearance
- Minimum loading space length25 ft
each loading space required by this section shall be at least 12 feet wide by 25 feet long (or deep)
- Minimum loading space width12 ft
each loading space required by this section shall be at least 12 feet wide by 25 feet long (or deep)
From the ordinance
For the purpose of these regulations, each loading space required by this section shall be at least 12 feet wide by 25 feet long (or deep), with at least 14 feet of overhead clearance. Each loading space shall have adequate, unobstructed means for the ingress and egress of vehicles, and a minimum aisle width of 22 feet.