Prince William County Unincorporated, Virginia · General provision
Sec. 32-250.204
Extracted standards
7 individual requirements pulled out of this section’s prose, each with the sentence it came from.
Lighting
- Light pole setbackSetbackThe distance a building must be held back from a lot line. from residential
All light fixtures/light poles shall be set back a minimum of one foot for every foot in height from any residential property line or right-of-way
- Maximum baseball/softball lighting50 fc
Fifty foot-candles in the infield and 30 foot-candles in the outfield
- Maximum basketball lighting30 fc
Thirty foot-candles for basketball courts
- Maximum football/soccer lighting50 fc
Fifty foot-candles for football/soccer fields
- Maximum golf lighting5 fc
Five foot-candles for golf related facilities
- Maximum lighting at residential boundary0.5 fc
Lighting levels shall not exceed 0.5 foot-candles at any common property line with property zoned, used as, or planned for residential or agricultural uses
- Maximum tennis lighting50 fc
Fifty foot-candles for tennis courts
From the ordinance
The average maintained lighting levels for recreational uses... shall not exceed: Fifty foot-candles in the infield... All light fixtures/light poles shall be set back a minimum of one foot for every foot in height from any residential property line or right-of-way. Lighting levels shall not exceed 0.5 foot-candles at any common property line...