Prince William County Unincorporated, Virginia · General provision

Sec. 32-250.204

Extracted standards

7 individual requirements pulled out of this section’s prose, each with the sentence it came from.

Lighting

  • All light fixtures/light poles shall be set back a minimum of one foot for every foot in height from any residential property line or right-of-way

  • Maximum baseball/softball lighting50 fc

    Fifty foot-candles in the infield and 30 foot-candles in the outfield

  • Maximum basketball lighting30 fc

    Thirty foot-candles for basketball courts

  • Maximum football/soccer lighting50 fc

    Fifty foot-candles for football/soccer fields

  • Maximum golf lighting5 fc

    Five foot-candles for golf related facilities

  • Maximum lighting at residential boundary0.5 fc

    Lighting levels shall not exceed 0.5 foot-candles at any common property line with property zoned, used as, or planned for residential or agricultural uses

  • Maximum tennis lighting50 fc

    Fifty foot-candles for tennis courts

From the ordinance

The average maintained lighting levels for recreational uses... shall not exceed: Fifty foot-candles in the infield... All light fixtures/light poles shall be set back a minimum of one foot for every foot in height from any residential property line or right-of-way. Lighting levels shall not exceed 0.5 foot-candles at any common property line...