Prince George County Unincorporated, Virginia · General provision

Article XIVA, Sec. 90-664

Dimensional standards

Servicing

Applies near
Chesapeake Bay
Geographic extent
Applies to all lands designated as Chesapeake Bay Preservation Areas, including resource protection areas (RPA) and resource management areas (RMA) as shown on the Official Preservation Area DistrictZoning districtA mapped area with one set of rules, identified by a code like R-1 or B-2. Map. RPA includes tidal wetlands, nontidal wetlands, tidal shores, and a 100-foot buffer adjacent to water bodies with perennial flow. RMA is 150 feet wide or includes floodplains, highly erodible soils (steep slopes >15%), highly permeable soils, and nontidal wetlands not in RPA.

Extracted standards

18 individual requirements pulled out of this section’s prose, each with the sentence it came from.

Landscaping & trees

  • Pervious surfaces for parking areas

    Pervious surfaces, such as grid and modular pavements, shall be used for any required parking area, alley or other low traffic driveway

  • Protective barrier distance from drip-line5 ft

    suitable protective barriers, like safety fencing, shall be erected five feet outside the drip-line of any around [sic] any tree or stand of trees to be preserved.

  • Minimum DBH for replacement trees1.5 in

    Replacement trees shall be a minimum one and one-half inches DBH at the time of planting.

  • Minimum DBH for tree preservation6 in

    Existing trees over six inches in diameter at breast height (DBH) shall be preserved outside the approved construction footprint.

  • Tree replacement ratio3 ratio

    replacement of existing trees and other vegetation will be achieved at a three planted trees to one removed.

Other

  • achieve a 40-percent reduction in nonpoint source pollution from agricultural uses.

  • Seaward buffer encroachment limit50 ft

    The encroachment may not extend into the seaward 50 feet of the buffer area.

  • Resource Protection Area buffer width100 ft

    a vegetated buffer area not less than 100 feet in width located adjacent to and landward of the components listed in subsections (a) through (d) above, and along both sides of any water body with perennial flow.

  • the post-development nonpoint source pollution runoff load shall not exceed the pre-development load, based on the average total phosphorus loading of 0.45 pounds per acre per year.

  • Any development or redevelopment exceeding 2,500 square feet of land disturbance shall be accomplished through a plan of development process

  • Redevelopment pollution reduction10 pct

    the nonpoint source pollution load shall be reduced by at least ten percent.

  • Reserve sewage disposal site required

    A reserve sewage disposal site with a capacity at least equal to that of the primary sewage disposal site shall be provided on each lot or parcel proposed for new construction.

  • Resource Management Area width150 ft

    the resource management area shall be provided contiguous to the entire inland boundary of the resource protection area, and shall consist of an area 150 feet in width

  • Septic system pump-out frequency5 years

    Systems shall be pumped out at least once every five years

Parking

From the ordinance

The Chesapeake Bay Preservation Area (CBPA) Overlay District shall apply to all lands identified as a CBPAs as designated by the county and as shown on the Official Preservation Area District Map.
Article XIVA, Sec. 90-664