Powhatan County Unincorporated, Virginia · General provision
Sec. 83-434(f)(5)a
Dimensional standards
Lot
Servicing
- Applies within
- 1,000 ft
Extracted standards
5 individual requirements pulled out of this section’s prose, each with the sentence it came from.
Other
- Minimum fence heightMaximum heightThe tallest a building may be, given in feet, in storeys, or both — whichever binds first.6 ft
Be surrounded by a solid fence or concrete or masonry wall that is at least six feet high.
- Fence setbackSetbackThe distance a building must be held back from a lot line. from adjacent property50 ft
Located no less than 50 feet from any adjacent property.
- Fence setbackSetbackThe distance a building must be held back from a lot line. from public right-of-way100 ft
Located no less than 100 feet from any public right-of-way.
- Minimum distance from residential districts1,000 ft
Be located at least 1,000 feet from any existing residential district, school, or child day care center.
- Minimum site area3 acresacre43,560 square feet — about the size of an American football field without the end zones.
Be located on a site with an area of at least three acres.
From the ordinance
Hazardous material collection sites shall: Be located on a site with an area of at least three acres; Be located at least 1,000 feet from any existing residential district, school, or child day care center; Be surrounded by a solid fence or concrete or masonry wall that is at least six feet high, located no less than 100 feet from any public right-of-way, and located no less than 50 feet from any adjacent property; and Comply with state hazardous material management regulations.