Lovettsville, Virginia · General provision

Sec 42-478

Dimensional standards

Servicing

Applies near
flood hazard areas
Geographic extent
All identified flood hazard areas where base flood elevations have been provided in the FIS or generated by a certified professional

Extracted standards

10 individual requirements pulled out of this section’s prose, each with the sentence it came from.

Floodplain

  • Flood resistant materials below regulatory flood protection elevation

    Be constructed entirely of flood resistant materials below the regulatory flood protection elevation;

  • Enclosed area below regulatory flood protection elevation use

    Not be designed or used for human habitation, but shall only be used for parking of vehicles, building access, or limited storage of maintenance equipment used in connection with the premises.

  • All manufactured homes placed, or substantially improved, on individual lots or parcels, must meet all the requirements for new construction, including the elevation and anchoring requirements in sections 42-476 and 42-477.

  • The total net area of all openings must be at least one (1) square inch for each square foot of enclosed area subject to flooding.

  • Minimum number of openings for hydrostatic equalization2 count

    Provide a minimum of two openings on different sides of each enclosed area subject to flooding.

  • Nonresidential lowest floor elevation above BFE1.5 ft

    lowest floor, including basement, elevated to or above the base flood level plus 18 inches.

  • Nonresidential floodproofing elevation above BFE2 ft

    floodproofed ... below the elevation corresponding to the BFE plus two feet

  • The bottom of all required openings shall be no higher than one foot above the adjacent grade.

  • Recreational vehicle 180-day limit180 days

    Be on the site for fewer than 180 consecutive days, be fully licensed and ready for highway use

  • Residential lowest floor elevation above BFE1.5 ft

    lowest floor, including basement, elevated to or above the base flood level plus 18 inches.

From the ordinance

New construction or substantial improvement of any residential structure (including manufactured homes) in zones A1-30, AE, AH and A with detailed base flood elevations shall have the lowest floor, including basement, elevated to or above the base flood level plus 18 inches.