Lovettsville, Virginia · General provision

Sec 42-304

Extracted standards

3 individual requirements pulled out of this section’s prose, each with the sentence it came from.

Other

  • Angled roof installation6 in

    On an angled roof, the system must be installed at the same angle as the roof on which it is installed with a maximum distance between the roof and highest edge or surface of the system, measured perpendicular to the roof, of 6 inches.

  • Building-mounted PV allowed in all districts

    Building-mounted PV systems are permitted in all zoning districts as an accessory use to any permitted principal use on the same lot provided they generate electricity for a use on the same property rather than for commercial or utility generation purposes.

  • On a flat roof, the highest point of the system may extend up to two (2) feet above the roof to which it is attached on a residential building and up to six (6) feet above the roof to which it is attached on a nonresidential building.

From the ordinance

Building-mounted PV systems are permitted in all zoning districts as an accessory use to any permitted principal use on the same lot provided they generate electricity for a use on the same property rather than for commercial or utility generation purposes.
Sec 42-304