- ProhibitedProhibitedNot allowed in the district at all, short of rezoning or a variance. in HistoricHistoric districtAn area where exterior changes need design review to protect its character. Overlay DistrictOverlay districtA second set of rules laid over the base district, adding requirements without replacing it. and Ridge Protection Feature SetbackSetbackThe distance a building must be held back from a lot line.. Special exception required in many districts.
Extracted standards
12 individual requirements pulled out of this section’s prose, each with the sentence it came from.
Other
- Maximum directional antenna heightMaximum heightThe tallest a building may be, given in feet, in storeys, or both — whichever binds first. (over 60 ft structures)10 ft
Directional or panel antennas must not exceed 10 feet in height or 2 feet in width.
- Maximum directional antenna heightMaximum heightThe tallest a building may be, given in feet, in storeys, or both — whichever binds first. (up to 60 ft structures)5 ft
Directional or panel antennas must not exceed 5 feet in height and 1 foot in width.
- Maximum dish antenna diameter (over 60 ft structures)6 ft
Dish antennas must not exceed 6 feet in diameter and must be screened from public view.
- Maximum dish antenna diameter (up to 60 ft structures)3 ft
Dish antennas must not exceed 3 feet in diameter.
- Maximum omnidirectional antenna heightMaximum heightThe tallest a building may be, given in feet, in storeys, or both — whichever binds first. (over 60 ft structures)20 ft
Omnidirectional or whip antennas must not exceed 20 feet in height or 7 inches in diameter.
- Maximum omnidirectional antenna heightMaximum heightThe tallest a building may be, given in feet, in storeys, or both — whichever binds first. (up to 60 ft structures)8.5 ft
Omnidirectional or whip antennas must not exceed 8½ feet in height and 3 inches in diameter.
- Antenna hub site screening heightMaximum heightThe tallest a building may be, given in feet, in storeys, or both — whichever binds first.8 ft
Related unmanned equipment must be screened by a solid fence, wall or berm 8 feet in height with an evergreen hedge.
- Maximum related unmanned equipment gross floor area500 sqftsq ftSquare feet. An acre is 43,560 sq ft; a typical suburban lot is 7,000–10,000.
Related unmanned equipment must not exceed a cumulative total of 500 square feet of gross floor area per service provider on each site.
- Maximum related unmanned equipment heightMaximum heightThe tallest a building may be, given in feet, in storeys, or both — whichever binds first.12 ft
Related unmanned equipment must not exceed 12 feet in height.
- Maximum heightMaximum heightThe tallest a building may be, given in feet, in storeys, or both — whichever binds first. of monopole or tower199 ft
Monopoles, including any antennas, must not exceed 199 feet in height, as measured from the natural ground elevation.
- Removal after cessation of use90 days
The monopole and all related unmanned equipment must be removed and the site restored within 90 days after cessation of use.
- SetbackSetbackThe distance a building must be held back from a lot line. ratio from property lines0.2 ft per ft heightMaximum heightThe tallest a building may be, given in feet, in storeys, or both — whichever binds first.
Monopoles must be setback 1 foot for every 5 feet in height from any property line.
From the ordinance