Loudoun County Unincorporated, Virginia · General provision

Section 4.07.06.B

Dimensional standards

lot requirementsSTREETMIN LOT AREA500 acMAX HEIGHT20 ft
Plan view of the district’s stated lot requirements. Solid line: the property line. Dashed: the setback lines the ordinance imposes; a building must stay inside the tinted envelope. Drawn from the figures extracted below — illustrative, not a survey.

Extracted standards

5 individual requirements pulled out of this section’s prose, each with the sentence it came from.

Historic

Other

Setback

From the ordinance

The solar facility must be located on a parcel with a minimum size of 500 acres. Ground-mounted solar panels must not exceed 20 feet in height. All components of the solar facility must be set back a distance of at least 75 feet from all public roads and buildings and at least 25 feet from property lines. The solar facility must not be located within 1 mile of an airport unless certified. The solar facility must not be located within 1 mile of a Historic Resource.
Section 4.07.06.B