Sec. 86-247
Extracted standards
7 individual requirements pulled out of this section’s prose, each with the sentence it came from.
Other
- Access not from minor residential street
Access shall not be from a minor residential street
- Excavation setbackSetbackThe distance a building must be held back from a lot line. from dwelling or platted subdivision200 ft
at least 200 feet from any dwelling or any and all property lines in any platted subdivision
- Excavation setbackSetbackThe distance a building must be held back from a lot line. from adjoining property lines50 ft
The excavations shall be confined to areas located at least 50 feet from all adjoining property lines
- Excavation setbackSetbackThe distance a building must be held back from a lot line. from residential or business districtZoning districtA mapped area with one set of rules, identified by a code like R-1 or B-2.100 ft
at least 100 feet from any and all adjoining property lines in any residential or any business district
- Excavation setbackSetbackThe distance a building must be held back from a lot line. from right-of-way200 ft
The excavation shall be confined to areas located at least 200 feet from the right-of-way lines of any existing or platted street, road or highway
- Building with machinery setbackSetbackThe distance a building must be held back from a lot line. from residential/business districtZoning districtA mapped area with one set of rules, identified by a code like R-1 or B-2.600 ft
Any building containing power-driven or power-producing machinery or equipment shall be located at least 600 feet from all adjacent property in any residential or business district
- Plan of systematic operation and rehabilitation required
A specific plan of systematic operation and simultaneous rehabilitation shall be submitted to and approved by the board of Supervisors
From the ordinance
Resource extraction: excavations at least 50 ft from adjoining property lines, 100 ft from residential/business district, 200 ft from dwelling or platted subdivision; 200 ft from right-of-way; buildings with machinery 600 ft from residential/business district; access not from minor residential street; plan of operation and rehabilitation required.