Kenbridge, Virginia · General provision

Sec. 12-5

Extracted standards

21 individual requirements pulled out of this section’s prose, each with the sentence it came from.

Other

  • In the industrial M-2 district, there shall be provided and maintained on the same premises at least one additional space for each 25,000 square feet of gross floor area or major fraction thereof up to 100,000 square feet of gross floor area used for storage or warehousing.

  • plus one additional space for each 20,000 square feet of gross floor area in excess of the first 10,000 square feet of gross floor area

  • Gross floor area threshold for loading space requirement (B-1, M-1)5,000 sqftsq ftSquare feet. An acre is 43,560 sq ft; a typical suburban lot is 7,000–10,000.

    In the business and industrial M-1 districts, every building or part thereof hereafter constructed, having a gross floor area of 5,000 square feet or more which is to be occupied by any business or industrial use or other use requiring the receipt or delivery of material or merchandise by vehicle, shall provide at least one off-street loading space

  • Minimum loading space distance from residential lot50 ft

    no loading space shall be located closer than 50 feet to another lot in any residential district unless completely enclosed within the building or by a wall or uniformly painted solid board fence not less than eight feet high

  • 15 feet high

  • Minimum loading space length35 ft

    35 feet long

  • Minimum loading space width12 ft

    Each loading space shall be at least 12 feet wide

  • Parking lot access must comply with state standards

    Vehicular entrances and exits must comply with state standards.

  • there shall be installed and maintained an ornamental concrete, or masonry wall or solid board fence or chain link fence interwoven with aluminum slats or dense evergreen planting at least five feet high unless natural conditions provide effective screening

  • Parking lot lighting must direct light away from residential property

    Any lighting equipment shall be so arranged as to direct the light and glare away from nearby residential property and public streets.

  • Parking lot paving required

    All such public or private parking lots, except in industrial districts, shall be paved to provide a hard surface of dustless construction.

  • except in those cases where there are existing parking areas in such districts on both sides of the proposed parking area and located within 150 feet of the proposed parking area, then the proposed parking area need set back only as far as the average setback of the parking area on both sides

  • All parking areas shall be set back 25 feet from the established right-of-way line

Parking

From the ordinance

In all districts, off-street parking areas shall be provided in connection with and as an accessory use to each and every use on the premises to be served
Sec. 12-5