Sec. 5-2000.D
Extracted standards
6 individual requirements pulled out of this section’s prose, each with the sentence it came from.
Other
- AccessoryAccessory useA secondary activity customarily incidental to the main use of the lot — a garage, a home office. structure heightMaximum heightThe tallest a building may be, given in feet, in storeys, or both — whichever binds first. exception125 pct
structures which are accessory to a single-story structure may be constructed to a maximum height not exceeding one hundred twenty-five percent (125%) of the height of the principal structure.
- AccessoryAccessory useA secondary activity customarily incidental to the main use of the lot — a garage, a home office. structure separation from principal20 ft
In cases where this is permitted, the accessory structure shall be separated from the principal residential structure by a distance of at least twenty (20) feet.
- AgriculturalAgricultureRaising crops or livestock, generally including the structures that serve them. structure heightMaximum heightThe tallest a building may be, given in feet, in storeys, or both — whichever binds first. exemption
Buildings or structures used in conjunction with a bona fide agricultural use or operation in the rural/agricultural conservation (RAC) district shall be exempt from the height limits specified in the zoning district regulations.
- Attached structure heightMaximum heightThe tallest a building may be, given in feet, in storeys, or both — whichever binds first. exception25 pct
may be permitted to exceed the height stipulated in the schedule of zone regulations by no more than twenty-five percent (25%) if attached to a building
- Freestanding structure heightMaximum heightThe tallest a building may be, given in feet, in storeys, or both — whichever binds first. exception100 ft
or to a maximum of one hundred (100) feet if freestanding.
- Solar device heightMaximum heightThe tallest a building may be, given in feet, in storeys, or both — whichever binds first. exception5 ft
Solar heating and solar collection devices provided such devices do not exceed by more than five (5) feet the otherwise permitted maximum height for the zone in which they are located.
From the ordinance
Church spires, belfries, cupolas, monuments, chimneys, utility transmission towers, water towers, fire towers, cooling towers, elevator penthouses, monuments or towers used in the manufacturing process, or other similar structures, may be permitted to exceed the height stipulated in the schedule of zone regulations by no more than twenty-five percent (25%) if attached to a building or to a maximum of one hundred (100) feet if freestanding.