Article XII, § 171-51 through § 171-59
Dimensional standards
Servicing
- Geographic extent
- Applies to community facility, commercial and industrial uses in all districts
Extracted standards
8 individual requirements pulled out of this section’s prose, each with the sentence it came from.
Other
- Minimum distance of loading access from street intersection50 ft
The entrances and exits to all required accessory off-street loading berths shall be located at least 50 feet from the intersection of any two streets.
- Minimum vertical clearance15 ft
Off-street loading berths, opened or enclosed, shall have minimum dimensions of length: 55 feet; width: 12 feet; and vertical clearance: 15 feet.
- Minimum loading berth length55 ft
Off-street loading berths, opened or enclosed, shall have minimum dimensions of length: 55 feet; width: 12 feet; and vertical clearance: 15 feet.
- Minimum loading berth width12 ft
Off-street loading berths, opened or enclosed, shall have minimum dimensions of length: 55 feet; width: 12 feet; and vertical clearance: 15 feet.
- Location of loading facilities
All off-street loading facilities shall be located in the rear of the principal building.
- Minimum distance of screening from vehicular entrances/exits15 ft
Such screening shall not be located within 15 feet of normal vehicular entrances and exits.
- Screening requirements when adjacent to residences
All permitted or required open off-street loading berths located adjacent to residences or a residential district shall be screened by a strip at least four feet wide, densely planted with shrubs or trees at least four feet high, or a wall or barrier of uniformly painted fence of fire-resistant material, at least six feet high but not more than eight feet high, with not more than 50% of the fence open.
- Surfacing requirement
All permitted or required open off-street loading berths and parking shall be surfaced with asphalt or concrete and constructed to provide adequate drainage.
From the ordinance
Off-street loading berths shall have minimum dimensions of length: 55 feet; width: 12 feet; and vertical clearance: 15 feet. Entrances and exits shall be located at least 50 feet from the intersection of any two streets. All permitted or required open off-street loading berths and parking shall be surfaced with asphalt or concrete. All off-street loading facilities shall be located in the rear of the principal building.