Extracted standards
2 individual requirements pulled out of this section’s prose, each with the sentence it came from.
Other
- Maximum earthborn vibration displacement
Vibration displacement shall not exceed D = K/f, where K is from Table 78-130.3(c) and f is frequency in cycles per second. Measurements at adjacent lot line or residential district boundary.
- Measurement equipment
Instrument capable of simultaneously measuring in three mutually perpendicular directions.
From the ordinance
No activity or operation shall cause or create earthborn vibrations in excess of the displacement values given in this section. Maximum permitted displacements determined by D = K/f.