Herndon, Virginia · General provision

Sec. 78-80.4(j)

Extracted standards

6 individual requirements pulled out of this section’s prose, each with the sentence it came from.

Other

  • Maximum canopy lighting intensity12 foot-candles

    Lighting for canopies for drive-through service shall not exceed an average of 12 foot-candles as measured at ground level

  • Minimum distance of ingress/egress from property line10 ft

    shall be located at least ten feet from the property line of adjoining parcels.

  • Minimum landscaped buffer width along street frontages15 ft

    a landscaped buffer a minimum of 15 feet wide shall be provided along all street frontages

  • A masonry screening wall a minimum of six feet high shall be provided along any side lot or rear lot line adjacent to a residential use or district.

  • Minimum stacking lane length180 ft

    and 180 feet long as measured from the drive-through window

  • Minimum stacking lane width12 ft

    The stacking lane shall be a minimum of 12 feet wide

From the ordinance

Drive-through service accessory standards: stacking lane 12 ft wide, 180 ft long, 15 ft buffer, 10 ft ingress/egress setback, 12 fc canopy lighting, 6 ft screening wall.
Sec. 78-80.4(j)