Extracted standards
6 individual requirements pulled out of this section’s prose, each with the sentence it came from.
Setback
- DistrictZoning districtA mapped area with one set of rules, identified by a code like R-1 or B-2. setbackSetbackThe distance a building must be held back from a lot line. compliance
Small wind energy systems shall meet all setback requirements for primary structures for the zoning district in which the small wind energy system is located in addition to the requirements set forth above.
- Easement required
Also, a recorded deed shall provide an easement equal to 150 percent of the tower height plus the blade length around the tower and the area within the easement shall be designated for no other use.
- Property line clearance10 ft
Additionally, no portion of the small wind energy system, including guy wire anchors, may extend closer than ten feet to the property line.
- SetbackSetbackThe distance a building must be held back from a lot line. from dwellings and power lines
and a distance equal at least to 150 percent of the tower height plus blade length from any dwelling inhabited by humans on neighboring property and from overhead power lines.
- SetbackSetbackThe distance a building must be held back from a lot line. from property lines
The small wind energy system shall be set back a distance at least equal to 110 percent of the height of the tower plus the blade length from all adjacent property lines
- SetbackSetbackThe distance a building must be held back from a lot line. reduction by consent
These setbacks may be reduced by notarized consent of the owner of the property on which the requested small wind energy system is to be erected and the adjacent landowner whose property line or dwelling falls within the specified distance.
From the ordinance
The small wind energy system shall be set back a distance at least equal to 110 percent of the height of the tower plus the blade length from all adjacent property lines