Lot
- Maximum units per structure10 count
There shall be no more than 10 units contained in any one structure.
The minimum lot size for apartment developments is 10,000 square feet for an apartment structure having three units, with an additional 2,000 square feet of lot area for each additional unit above three. There shall be no more than 10 units contained in any one structure.
Other
- Cul-de-sac radius50 ft
The radius of cul-de-sac shall be at least 50 feet.
- Curbs and gutters required
Concrete curb and gutters shall be installed along both sides of all new streets within the development.
- Minimum distance between structures40 ft
No structure shall be located closer than 40 feet at any point to another structure.
- Maximum dwelling unitsDwelling unitOne independent home: its own kitchen, bathroom and entrance. per cul-de-sac20 count
No more than 20 dwelling units shall be served by any cul-de-sac.
- Open spaceOpen spaceLand a development must leave unbuilt, sometimes required to be usable or planted. requirement4,000 sqftsq ftSquare feet. An acre is 43,560 sq ft; a typical suburban lot is 7,000–10,000. per 5 units
Four thousand square feet of open space shall be provided per each five apartment units.
- Public water and sewer required
All apartments must be connected to a public water and public sewer system as required by §§ 68-1 and 68-2 of the Town Code.
- Smoke detectors required
All rental units must have smoke detectors.
- Trash storage screening
Exterior storage areas for trash and rubbish shall be required by the Town. Such areas shall be well-screened on three sides and contain vermin proof containers.
- Minimum walkway width4 ft
Walkways of a minimum of four feet in width, constructed of concrete or brick, shall be installed from central parking areas to all apartment structures served by such parking areas.
Parking
- Parking area entrance width12 ft
Entrance and exit ways to parking areas shall have a minimum width of 12 feet for each lane of traffic entering or leaving the site but shall at no time exceed 30 feet in width at the street line.
From the ordinance
The minimum lot size for apartment developments is 10,000 square feet for an apartment structure having three units, with an additional 2,000 square feet of lot area for each additional unit above three. There shall be no more than 10 units contained in any one structure. Minimum lot width shall be 50 feet at the setback line. Maximum building height shall be 45 feet from grade.
Parking requirements
{