Chesapeake, Virginia · General provision

§ 18-201

Extracted standards

6 individual requirements pulled out of this section’s prose, each with the sentence it came from.

Other

  • Boundary line accuracy

    Boundary, setback and zoning lines: one foot per one thousand (1:1,000) feet.

  • Existing features accuracy5 ft

    Existing structures, utilities and other topographic features: within five (5) feet.

  • Maximum contour interval10 ft

    Existing topography at a maximum of ten (10) foot contour intervals.

  • Proposed features accuracy5 ft

    Proposed structures, roads, parking lots and other improvements: within five (5) feet.

  • Maximum sheet size

    At least one rendering of the site plan shall be provided on a sheet not exceeding 11 inches by 17 inches in size.

  • Minimum sheet size

    Not smaller than 8½ inches by 11 inches in size.

From the ordinance

The preliminary site plan application shall contain the following information: ... (including) existing topography at a maximum of ten (10) foot contour intervals ... dimensioned to at least the following standards for accuracy: Boundary, setback and zoning lines: one foot per one thousand (1:1,000) feet; Existing structures, utilities and other topographic features: within five (5) feet; Proposed structures, roads, parking lots and other improvements: within five (5) feet.