Accomack County Unincorporated, Virginia · General provision
Towers and Antennas regulations (likely Sec. 106-237)
Dimensional standards
Height & bulk
- Minimum landscaping
- 4%
Uses
Extracted standards
4 individual requirements pulled out of this section’s prose, each with the sentence it came from.
Fencing & walls
- Minimum security fence heightMaximum heightThe tallest a building may be, given in feet, in storeys, or both — whichever binds first.6 ft
Towers shall be enclosed by security fencing not less than six feet in height
Landscaping & trees
- Minimum landscaped buffer width4 ft
The standard buffer shall consist of a landscaped strip at least four-feet wide outside the perimeter of the facilities.
- Tree protection radius200 ft
Existing trees within 200 feet of the tower shall not be removed
Other
- SetbackSetbackThe distance a building must be held back from a lot line. from off-site residential structure400 ft
The tower must be set back from any off-site residential structure no less than 400 feet.
From the ordinance
To permit co-location, the tower shall be designed and constructed to permit extensions to a maximum height of 199 feet. ... The tower must be set back from any off-site residential structure no less than 400 feet.