Extracted standards
9 individual requirements pulled out of this section’s prose, each with the sentence it came from.
Lighting
- Hours of illumination for institutional/commercial/industrial adjacent to residential
Institutional uses, commercial uses, and industrial uses that are adjacent to existing residential development shall extinguish all exterior lighting, except lighting necessary for security or emergency purposes, within one hour after closing and shall not turn on such lights until within one hour of opening.
- Maximum color temperature3,000 K
All exterior lights shall be 3,000 Kelvin light color temperature or less.
- Maximum pole-mounted lighting heightMaximum heightThe tallest a building may be, given in feet, in storeys, or both — whichever binds first. in industrial districts30 ft
Any pole-mounted exterior lighting shall not exceed a height of 30 feet in height in industrial districts
- Maximum pole-mounted lighting heightMaximum heightThe tallest a building may be, given in feet, in storeys, or both — whichever binds first. in all other districts20 ft
and 20 feet in height in all other districts.
- Maximum spillover light at adjoining commercial/street0.5 fc
Spillover light shall not exceed 0.5 foot candles at adjoining streets, commercial use, and mixed use
- Maximum spillover light at adjoining residential0.1 fc
Spillover light shall not exceed 0.1 foot candles at adjoining residential properties
- Moving, blinking, flashing lights prohibitedProhibitedNot allowed in the district at all, short of rezoning or a variance.
There shall be no moving, blinking, flashing, or wrap around bands of lighting on the exterior or interior of a building or seen from a public right-of-way.
- ProhibitedProhibitedNot allowed in the district at all, short of rezoning or a variance. lighting type
The use of mercury vapor lights shall be prohibited in any exterior lighting applications, except for under-canopy lighting for gasoline pump islands, bank, or other drive-through or drive-in facilities.
- Window lighting prohibitedProhibitedNot allowed in the district at all, short of rezoning or a variance.
Window lighting is prohibited in either the interior or exterior of windows.
From the ordinance
Spillover light shall not exceed 0.5 foot candles at adjoining streets, commercial use, and mixed use and shall not exceed 0.1 foot candles at adjoining residential properties.