Chesapeake, Virginia · General provision

Sec. 13-604

Dimensional standards

lot requirementsSTREETMin width 50 ftMIN LOT AREA2,000 sq ftMAX HEIGHT199 ft
Plan view of the district’s stated lot requirements. Solid line: the property line. Dashed: the setback lines the ordinance imposes; a building must stay inside the tinted envelope. Drawn from the figures extracted below — illustrative, not a survey.

Extracted standards

13 individual requirements pulled out of this section’s prose, each with the sentence it came from.

Lighting

  • Tower illumination

    Communication towers shall be illuminated as required by the Federal Aviation Administration. However, no lighting shall be incorporated if not required by either of those agencies, or specified by the city council as a condition of the use permit, or by the planning commission or planning director in the approval of a site plan.

Other

  • Deciduous trees (over 200 ft)2.5 in

    one (1) row of deciduous trees, with a minimum caliper of two and one-half (2½) inches at time of planting and spaced not more than forty (40) feet apart

  • Evergreen shrubs (200 ft or less)5 ft

    at least one (1) row of evergreen shrubs capable of forming a continuous hedge at least five (5) feet in height shall be provided, with individual plantings spaced not more than five (5) feet apart

  • Evergreen trees (200 ft or less)1.75 in

    at least one (1) row of evergreen trees with a minimum caliper of one and three-fourths (1¾) inches at the time of planting and spaced not more than twenty-five (25) feet apart

  • Landscaping installation

    All required landscaping shall be installed according to established planting procedures using good quality plant materials.

  • Landscaping maintenance1 year

    replacing unhealthy or dead plant materials within one (1) year or by the next planting season, whichever comes first

  • Minimum cellular providers accommodated2 providers

    all communication towers shall be designed and constructed to accommodate at least two (2) cellular providers

  • Stealth tower maintenance

    Stealth towers shall be maintained in substantially the same condition as when first built for as long as the tower is standing.

  • Tower finish (200 ft or less)

    Communication towers two hundred (200) feet or less in height shall have a galvanized finish, be painted silver, or be a natural grey in color.

  • Tower painting (over 200 ft)

    Communication towers more than two hundred (200) feet in height shall be painted in accordance with regulations of the Federal Aviation Administration.

  • Tower removal after cessation1 year

    shall remove all structures and facilities from the site on which the tower is located... within one (1) year of cessation of all use of the tower site

  • Tower visual impact

    The communication towers shall also be designed to be as unobtrusive as possible to reduce their visual impact.

Signage

  • Signs on tower

    No signs shall be placed on a communication tower if visible beyond the site on which the tower is located.

From the ordinance

Communication towers shall only be placed on a lot having a minimum area of two thousand (2,000) square feet... The minimum lot width for all communication tower sites shall be fifty (50) feet... shall not construct a communication tower or antenna in excess of one hundred ninety-nine (199) feet in height
Sec. 13-604

Parking requirements

{
  "communication_tower": "2 spaces"
}