Dimensional standards
Lot
Height & bulk
Uses
Conditional / special use1
Accessory2
Extracted standards
10 individual requirements pulled out of this section’s prose, each with the sentence it came from.
Design
- Multiple use required
Towers must accommodate at least 2 cellular providers.
Height
Max height 199 ft, except 500 ft in industrial/rural overlay.
Other
- Illumination requirements
Only FAA-required lighting.
- Painting requirements
Towers ≤200 ft: galvanized/silver/natural grey; >200 ft per FAA.
- Screening requirements
For towers ≤200 ft: one row evergreen shrubs (5 ft high, spaced ≤5 ft) and one row evergreen trees (1.75 in caliper, spaced ≤25 ft). For >200 ft: additional row deciduous trees (2.5 in caliper, spaced ≤40 ft).
- SetbackSetbackThe distance a building must be held back from a lot line. from nonresidential property line25 ft
Setback from nonresidential property lines: 25 ft.
- SetbackSetbackThe distance a building must be held back from a lot line. from residential property line50 ft
Setback from property lines abutting residential: 50 ft.
- SetbackSetbackThe distance a building must be held back from a lot line. from residential structure200 ft
No tower within 200 ft or 110% of height from residential structure.
- SetbackSetbackThe distance a building must be held back from a lot line. from street100 ft
Setback from streets: 100 ft.
Parking
- Minimum parkingMinimum parkingThe number of off-street spaces a development must provide before it may open. spaces2 spaces
Minimum 2 paved parking spaces per tower.
From the ordinance
Communication towers require a conditional use permit. Setbacks: 50 ft from residential property lines, 25 ft from nonresidential, 100 ft from streets, 200 ft or 110% of height from residential structures. Min lot area 2,000 sqft, min width 50 ft, max height 199 ft. Parking: 2 spaces.