Amherst County Unincorporated, Virginia · General provision

918

Dimensional standards

Uses

Conditional / special use1

Extracted standards

6 individual requirements pulled out of this section’s prose, each with the sentence it came from.

Noise

  • Noise limit

    Noise levels associated with small wind energy systems shall not exceed the noise levels required in the Amherst County Noise Ordinance

Other

  • Blade clearance above structures within 150 ft10 ft

    The lowest point of the arc of the blade shall also be ten (10) feet above the height of any structure within one hundred fifty (150) feet of the base.

  • Blade clearance from ground15 ft

    The minimum distance between the ground and any protruding blades utilized on a small wind energy system shall be fifteen (15) feet

  • The supporting tower shall also be enclosed with a six-foot tall fence with a lockable gate

Setback

From the ordinance

The tower height shall not exceed a maximum height of one hundred (100) feet. The minimum distance between the ground and any protruding blades... shall be fifteen (15) feet... The wind energy system shall be set back two (2) times the height of the tower height plus blade length from the property line.