912.01-912.07
Dimensional standards
Uses
Permitted by right1
Extracted standards
7 individual requirements pulled out of this section’s prose, each with the sentence it came from.
Lot
- Side yardYardThe open space left between a building and its lot line — the space a setback creates. at ends of group16 ft
There shall be a side yard of not less than sixteen (16) feet in width at each end of a group of units
Other
- Common area percentage10 pct
Each townhouse development shall provide at least ten (10) percent of the development site for areas of common use
- Max lot coverageLot coverageThe share of a lot that buildings may cover, as a percentage. end/corner40 pct
and for end and/or corner lots shall be forty (40) percent
- Max lot coverageLot coverageThe share of a lot that buildings may cover, as a percentage. interior50 pct
The maximum lot coverage for interior townhouse lots for sale shall be fifty (50) percent
- Perimeter yardYardThe open space left between a building and its lot line — the space a setback creates. when abutting R-150 ft
except where the development is within or abuts a R-1 Residential District, in which case the perimeter yard shall be at least fifty (50) feet
- Perimeter yardYardThe open space left between a building and its lot line — the space a setback creates.25 ft
Each townhouse development shall have a perimeter yard on the rear and side property lines of the total site equal to at least twenty-five (25) feet
- Underground utilities
All utilities shall be underground.
From the ordinance
Each townhouse shall be located on a lot of not less than 1,200 sq ft... front yard 10 ft... rear yard 25 ft... height no more than 40 ft... max lot coverage 50% interior, 40% end/corner... common areas 10%...