Sec. 22-27-9.8
Dimensional standards
Extracted standards
53 individual requirements pulled out of this section’s prose, each with the sentence it came from.
Other
- Maximum heightMaximum heightThe tallest a building may be, given in feet, in storeys, or both — whichever binds first. of attached antenna above building20 ft
The top of the attached antenna shall not be more than twenty feet (20') above the existing or proposed building or facility
- Maximum heightMaximum heightThe tallest a building may be, given in feet, in storeys, or both — whichever binds first. of non-concealed attached antenna above building20 ft
The top of the attached antenna shall not be more than twenty feet (20') above the existing or proposed building or facility
- Maximum heightMaximum heightThe tallest a building may be, given in feet, in storeys, or both — whichever binds first. of attached antenna above building20 ft
The top of the attached antenna shall not be more than twenty feet (20') above the existing or proposed building or facility
- Maximum heightMaximum heightThe tallest a building may be, given in feet, in storeys, or both — whichever binds first. of non-concealed attached antenna above building20 ft
The top of the attached antenna shall not be more than twenty feet (20') above the existing or proposed building or facility
- Maximum heightMaximum heightThe tallest a building may be, given in feet, in storeys, or both — whichever binds first. for non-broadcast TASF250 ft
under no circumstance shall any non-broadcast or non-emergency service facility exceed 250 feet in height.
- Maximum heightMaximum heightThe tallest a building may be, given in feet, in storeys, or both — whichever binds first. for concealed TASF in residential districts140 ft
Where permitted in residential districts the maximum height shall be 140 feet.
- Maximum heightMaximum heightThe tallest a building may be, given in feet, in storeys, or both — whichever binds first. for concealed TASF in other districts199 ft
In all other districts the maximum height shall be limited to 199 feet.
- Maximum heightMaximum heightThe tallest a building may be, given in feet, in storeys, or both — whichever binds first. for replacement TASF
The height of a replacement antenna support facility shall equal the height of the facility being replaced.
- Maximum heightMaximum heightThe tallest a building may be, given in feet, in storeys, or both — whichever binds first. for non-broadcast TASF (standard)199 ft
It is intended that all new non-broadcasting TASFs, other than amateur radio towers, be 199 feet or less in height.
- Maximum heightMaximum heightThe tallest a building may be, given in feet, in storeys, or both — whichever binds first. for amateur radio antenna
The maximum height regulations shall not apply to any such antenna; provided that such antenna shall be the minimum height which will reasonably achieve its intended purpose
- Maximum heightMaximum heightThe tallest a building may be, given in feet, in storeys, or both — whichever binds first. for broadcast facility
Height for broadcast facilities shall be evaluated on a case by case basis; the determination of height contained in the applicant's FCC Form 351/352 Construction Permit or application for Construction Permit and an FAA Determination of No Hazard (FAA Form 7460/2) shall be considered prima facie evidence of the antenna support facility height required for such broadcast facilities.
- Maximum heightMaximum heightThe tallest a building may be, given in feet, in storeys, or both — whichever binds first. for replacement TASF
The height of a replacement antenna support facility shall equal the height of the facility being replaced.
- Maximum heightMaximum heightThe tallest a building may be, given in feet, in storeys, or both — whichever binds first. for non-broadcast TASF (standard)199 ft
It is intended that all new non-broadcasting TASFs, other than amateur radio towers, be 199 feet or less in height.
- Maximum heightMaximum heightThe tallest a building may be, given in feet, in storeys, or both — whichever binds first. for amateur radio antenna
The maximum height regulations shall not apply to any such antenna; provided that such antenna shall be the minimum height which will reasonably achieve its intended purpose
- Maximum heightMaximum heightThe tallest a building may be, given in feet, in storeys, or both — whichever binds first. increase for colocation20 ft
A colocated or combined antenna or antenna array shall not exceed the maximum height prescribed in the Special Use Permit (if applicable) or increase the height of an existing facility by more than twenty feet (20')
- Maximum heightMaximum heightThe tallest a building may be, given in feet, in storeys, or both — whichever binds first. increase for colocation20 ft
A colocated or combined antenna or antenna array shall not exceed the maximum height prescribed in the Special Use Permit (if applicable) or increase the height of an existing facility by more than twenty feet (20')
- Maximum heightMaximum heightThe tallest a building may be, given in feet, in storeys, or both — whichever binds first. for mitigation TASF120 pct
TASF approved for mitigation shall not exceed one hundred and twenty (120%) percent of the height of the tallest TASF that is being mitigated.
- Maximum heightMaximum heightThe tallest a building may be, given in feet, in storeys, or both — whichever binds first. for mitigation TASF120 pct
TASF approved for mitigation shall not exceed one hundred and twenty (120%) percent of the height of the tallest TASF that is being mitigated.
- Maximum sound level for emergency generators70 dB
The sound level for emergency generators shall not exceed 70 dB at the property limits and testing shall only be between 9 a.m. to 4 p.m. Monday through Friday.
- Maximum sound level for emergency generators70 dB
The sound level for emergency generators shall not exceed 70 dB at the property limits and testing shall only be between 9 a.m. to 4 p.m. Monday through Friday.
- Spacing for high voltage signs20 ft
If more than two hundred twenty (220) volts are necessary for the operation of the facility and is utilized within the equipment compound or on the TASF, signs located every twenty feet (20') and attached to the fence or wall shall display in large, bold, high contrast letters (minimum height of each letter four inches (4")) the following: "HIGH VOLTAGE - DANGER."
- Spacing for high voltage signs20 ft
If more than two hundred twenty (220) volts are necessary for the operation of the facility and is utilized within the equipment compound or on the TASF, signs located every twenty feet (20') and attached to the fence or wall shall display in large, bold, high contrast letters (minimum height of each letter four inches (4")) the following: "HIGH VOLTAGE - DANGER."
- Maximum wind speed for balloon test20 mph
If the wind during the balloon test is above twenty miles per hour (20 mph) then the balloon test shall be postponed
- Maximum wind speed for balloon test20 mph
If the wind during the balloon test is above twenty miles per hour (20 mph) then the balloon test shall be postponed
- Minimum antenna arrays for TASF up to 120 feet3 count
All TASFs up to 120 feet in height shall be engineered and constructed to accommodate no less than three (3) antenna arrays.
- Minimum antenna arrays for TASF 121-150 feet5 count
All TASFs between 121 feet and 150 feet in height shall be engineered and constructed to accommodate no less than five (5) antenna arrays.
- Minimum antenna arrays for TASF over 151 feet6 count
All TASFs taller than 151 feet in height shall be engineered and constructed to accommodate no fewer than six (6) antenna arrays.
- Minimum antenna arrays for TASF up to 120 feet3 count
All TASFs up to 120 feet in height shall be engineered and constructed to accommodate no less than three (3) antenna arrays.
- Minimum antenna arrays for TASF 121-150 feet5 count
All TASFs between 121 feet and 150 feet in height shall be engineered and constructed to accommodate no less than five (5) antenna arrays.
- Minimum antenna arrays for TASF over 151 feet6 count
All TASFs taller than 151 feet in height shall be engineered and constructed to accommodate no fewer than six (6) antenna arrays.
- Minimum balloon diameter3 ft
The applicant shall arrange to raise a balloon of a color or material that provides maximum visibility and no less than three feet (3') in diameter
- Minimum balloon diameter3 ft
The applicant shall arrange to raise a balloon of a color or material that provides maximum visibility and no less than three feet (3') in diameter
- Minimum advertisement for balloon test7 days
The date, time and location of the balloon test shall be advertised in a locally distributed paper by the applicant at least seven (7) but no more than fourteen (14) days in advance of the test date.
- Minimum advertisement for balloon test7 days
The date, time and location of the balloon test shall be advertised in a locally distributed paper by the applicant at least seven (7) but no more than fourteen (14) days in advance of the test date.
- Minimum balloon test duration4 hours
The balloon shall be flown for at least four (4) consecutive hours during daylight hours on the date chosen.
- Minimum balloon test duration4 hours
The balloon shall be flown for at least four (4) consecutive hours during daylight hours on the date chosen.
- Minimum notice for balloon test14 days
The applicant shall inform in writing the Zoning Administrator, abutting property owners, elected Board of Supervisor, and appointed planning commissioners of the district of the date and times of the test at least fourteen (14) days in advance.
- Minimum notice for balloon test14 days
The applicant shall inform in writing the Zoning Administrator, abutting property owners, elected Board of Supervisor, and appointed planning commissioners of the district of the date and times of the test at least fourteen (14) days in advance.
- Minimum signage posting for balloon test72 hours
This signage shall be posted by the applicant a minimum of seventy-two (72) hours prior to the balloon test.
- Minimum signage posting for balloon test72 hours
This signage shall be posted by the applicant a minimum of seventy-two (72) hours prior to the balloon test.
- SetbackSetbackThe distance a building must be held back from a lot line. for non-breakpoint TASF from property lines
All other non-broadcast TASFs not constructed using breakpoint design technology; the minimum setback distance shall be equal to the height of the proposed TASF from all property lines.
- SetbackSetbackThe distance a building must be held back from a lot line. for concealed TASF in residential districts from structures
Concealed TASFs in residential districts not constructed using breakpoint design technology; the minimum setback distance shall be equal to the height of the proposed TASF from all existing structures.
- SetbackSetbackThe distance a building must be held back from a lot line. for breakpoint TASF
the minimum setback distance shall be equal to 110 percent of the distance from the top of the facility to the breakpoint level of the facility, or the minimum side and rear yard requirements, whichever is greater.
- SetbackSetbackThe distance a building must be held back from a lot line. for non-broadcast TASF from single-family dwellingSingle-family dwellingOne dwelling unit on its own lot, usually detached from its neighbours. in A-1 districtZoning districtA mapped area with one set of rules, identified by a code like R-1 or B-2.500 ft
In the Agricultural, General, A-1 district, new non-broadcast facilities shall be setback a minimum 500 feet from any single-family dwelling unit, either on the same zone lot or from all adjacent lots of record.
- SetbackSetbackThe distance a building must be held back from a lot line. for broadcast facility from single-family dwellingSingle-family dwellingOne dwelling unit on its own lot, usually detached from its neighbours.500 ft
New broadcast facilities and anchors shall be setback a minimum of 500 feet from any single-family dwelling unit located on the same parcel or lot
- SetbackSetbackThe distance a building must be held back from a lot line. for broadcast facility from adjacent lots
the antenna support structure (but not the anchors for a guyed structure) shall be setback a minimum of one foot (1') for every one foot (1') of antenna support facility height from all adjacent lots of record.
- SetbackSetbackThe distance a building must be held back from a lot line. for broadcast facility from adjacent lots (per foot of heightMaximum heightThe tallest a building may be, given in feet, in storeys, or both — whichever binds first.)1 ft
the antenna support structure (but not the anchors for a guyed structure) shall be setback a minimum of one foot (1') for every one foot (1') of antenna support facility height from all adjacent lots of record.
- SetbackSetbackThe distance a building must be held back from a lot line. for non-broadcast TASF from single-family dwellingSingle-family dwellingOne dwelling unit on its own lot, usually detached from its neighbours. in A-1 districtZoning districtA mapped area with one set of rules, identified by a code like R-1 or B-2.500 ft
In the Agricultural, General, A-1 district, new non-broadcast facilities shall be setback a minimum 500 feet from any single-family dwelling unit, either on the same zone lot or from all adjacent lots of record.
- SetbackSetbackThe distance a building must be held back from a lot line. for broadcast facility from single-family dwellingSingle-family dwellingOne dwelling unit on its own lot, usually detached from its neighbours.500 ft
New broadcast facilities and anchors shall be setback a minimum of 500 feet from any single-family dwelling unit located on the same parcel or lot
- SetbackSetbackThe distance a building must be held back from a lot line. for broadcast facility from adjacent lots
the antenna support structure (but not the anchors for a guyed structure) shall be setback a minimum of one foot (1') for every one foot (1') of antenna support facility height from all adjacent lots of record.
- SetbackSetbackThe distance a building must be held back from a lot line. for broadcast facility from adjacent lots (per foot of heightMaximum heightThe tallest a building may be, given in feet, in storeys, or both — whichever binds first.)1 ft
the antenna support structure (but not the anchors for a guyed structure) shall be setback a minimum of one foot (1') for every one foot (1') of antenna support facility height from all adjacent lots of record.
- Minimum letter heightMaximum heightThe tallest a building may be, given in feet, in storeys, or both — whichever binds first. for high voltage signs4 in
minimum height of each letter four inches (4")
- Minimum letter heightMaximum heightThe tallest a building may be, given in feet, in storeys, or both — whichever binds first. for high voltage signs4 in
minimum height of each letter four inches (4")
From the ordinance
One parking space is required for each TASF development area. The space shall be provided within the leased area, or equipment compound or the development area as defined on the site plan.
Parking requirements
{
"TASF": "1 space per development area"
}