Fluvanna County Unincorporated, Virginia · General provision

Article 25, Sec. 22-25-5

Extracted standards

14 individual requirements pulled out of this section’s prose, each with the sentence it came from.

Lighting

  • Lighting turned off after close of business

    All outdoor lighting fixtures shall be turned off after the close of business, unless needed for safety or security, in which case the lighting shall be reduced to the minimum level necessary.

  • Canopy lighting fixtures must be recessed

    The lighting fixture bulbs shall be recessed into a canopy ceiling so that the bottom of the fixture is flush with the ceiling and light is restrained to no more than eighty-five (85) degrees from vertical.

  • Maximum light angle from vertical for canopy fixtures85 deg

    light is restrained to no more than eighty-five (85) degrees from vertical.

  • Canopy sides shall not be illuminated

    Lights shall not be mounted on the top or sides (fascia) of the canopy, and the sides of the canopy shall not be illuminated.

  • Maximum average horizontal illumination for gas station canopies20 fc

    The lighting for new facilities (pump islands and under canopies) shall have a minimum of 1.0 footcandle at grade, and the average horizontal illumination cannot exceed 20 footcandles at grade level, subject to a uniformity ratio... no greater than 4:1.

  • Maximum average horizontal illumination for parking/display/loading areas5 fc

    Lighting for all parking, display and loading areas shall not exceed an average horizontal illumination level of 5 footcandles.

  • Spillover light... onto public roads and property in residential or agricultural zoning districts shall not exceed one-half (1/2) footcandle at the property line.

  • Maximum uniformity ratio for gas station canopies4 ratio

    subject to a uniformity ratio (ratio of average to minimum illuminance) no greater than 4:1.

  • Minimum illumination for gas station canopies1 fc

    The lighting for new facilities (pump islands and under canopies) shall have a minimum of 1.0 footcandle at grade...

  • Photometric plan required with application

    Any person submitting a site plan or applying for a building, electrical or sign permit to install outdoor lighting fixtures shall... submit evidence that the proposed work will comply with this article.

  • The lighting of roofs or portions thereof is prohibited.

  • Full shielding required

    All outdoor light fixtures except those exempted... shall be fully shielded.

  • Sign lighting mounting requirements

    Lighting fixtures used to illuminate an outdoor sign shall either be mounted on the ground sign or mounted on the top of the sign, and shall comply with shielding requirements.

  • The unshielded outdoor illumination of any building or landscaping is prohibited.

From the ordinance

All outdoor light fixtures except those exempted, or as otherwise specified in Article 15: Sign Regulations of this chapter, shall be fully shielded.
Article 25, Sec. 22-25-5