Chesterfield County Unincorporated, Virginia · General provision
Sec. 19.2-44
Extracted standards
5 individual requirements pulled out of this section’s prose, each with the sentence it came from.
Other
- Min basin aquatic bench width6 ft
Aquatic benches shall be placed around the perimeter of the permanent pool at the normal water surface elevation, not exceed 12 inches in depth, have a minimum width of 6 feet.
- Min basin fence heightMaximum heightThe tallest a building may be, given in feet, in storeys, or both — whichever binds first.6 ft
If a fence is used, the minimum height of the fence shall be six feet
- Min basin perimeter yardYardThe open space left between a building and its lot line — the space a setback creates. width50 ft
Basins on property located in an SR, SC, SU, TR, UR, or MU District... shall be enclosed by a minimum 50-foot wide vegetative perimeter yard
- Min basin safety bench width10 ft
Safety benches shall be located at the toe of the slope of the basin and shall be at least 10 feet wide.
- Max basin side slope ratio3 ratio
The side slopes above the normal water surface elevation in basins shall be no steeper than 3:1 (horizontal to vertical).
From the ordinance
All basins required by the Director of Environmental Engineering as either a stormwater management facility or a Best Management Practice (BMP)...