- Applies to all battery energy storage systems.
Extracted standards
5 individual requirements pulled out of this section’s prose, each with the sentence it came from.
Other
- Decommissioning agreement required
Prior to approval, applicant shall enter into written decommissioning agreement.
- Layered fire protection required
Sufficient layered fire protection approach as determined by Chesapeake Fire Department.
- Maximum lighting at lot line0.5 footcandles
Direct or reflected illumination does not exceed one-half (0.5) footcandles above background measured at the lot line.
- Minimum setbackSetbackThe distance a building must be held back from a lot line. from property lines300 ft
Any battery energy storage system shall be setback three hundred (300) feet from all property lines.
- Reduced setbackSetbackThe distance a building must be held back from a lot line. with risk analysis100 ft
City council may reduce distance to no less than 100 feet if independent risk analysis provided.