Sec. 4.14.3, 4.14.4, 4.14.5
Extracted standards
4 individual requirements pulled out of this section’s prose, each with the sentence it came from.
Other
- No adverse electrical disturbance on other lots
No electrical disturbance generated from a use of an industrial character shall adversely affect any activity, including the use of any machinery or equipment, on any other lot.
- Certified engineer's report required for industrial uses
Prior to the issuance of a zoning clearance or approval of a final site plan, each prospective occupant of a use of an industrial character shall submit a certified engineer's report.
- Maximum temperature increase at lot boundary1 degF
No heat or heated air shall be discharged such that a temperature increase of one degree Fahrenheit (1° F) or greater is measurable at or beyond the closest boundary line of an abutting lot.
- Vent orientation away from abutting lots in RA or residential districts
Vents, chimney stacks and other devices for emitting heat or heated air from a building shall be oriented away from abutting lots within the rural areas (RA) or any residential zoning district.
From the ordinance
No heat or heated air shall be discharged such that a temperature increase of one degree Fahrenheit (1° F) or greater is measurable at or beyond the closest boundary line of an abutting lot. No electrical disturbance generated from a use of an industrial character shall adversely affect any activity... Prior to the issuance of a zoning clearance or approval of a final site plan, each prospective occupant of a use of an industrial character shall submit a certified engineer's report.