Sec. 20C.6
Dimensional standards
Housing
- Single-familySingle-family dwellingOne dwelling unit on its own lot, usually detached from its neighbours.
- prohibitedProhibitedNot allowed in the district at all, short of rezoning or a variance.
- Two-family
- by_right
- Three-family
- by_right
- Four-plus family
- by_right
Uses
Permitted by right16
- multiple-family dwellings
- live-work dwelling units
- single-family attached dwellings
- retail sales and service
- restaurants, hotels, and lodging
- entertainment and recreation
- office
- artisan manufacturing
- commercial parking
- public and institutional uses
- community facility uses
- cultural amenity space
- public art
- temporary uses
- temporary construction uses and temporary storage yards
- stormwater management facilities
Conditional / special use1
Extracted standards
28 individual requirements pulled out of this section’s prose, each with the sentence it came from.
Lighting
- Color temperature range
All exterior fixtures must be fitted with lamps with a white light and color temperature between 2,000 and 3,000 Kelvin.
- Maximum light level at ground0.5 foot-candles
Light levels must not exceed 0.5-foot candles at the ground.
- Maximum exterior lighting lumens2,000 lumens
Exterior, outdoor lighting must not exceed 2,000 lumens.
- Maximum pole-mounted light fixture heightMaximum heightThe tallest a building may be, given in feet, in storeys, or both — whichever binds first.20 ft
Freestanding pole-mounted light fixtures (including the base) must not exceed 20 feet in height.
Other
- Civic space dedication per phase
The minimum area of required civic space, calculated based on the gross acreage of each phase, must be constructed and dedicated with each phase of development.
- Uses producing noise, vibrations, glare, heat, or electrical disturbance must be enclosed
Any use producing noise, vibrations, glare and heat, or electrical disturbance that is subject to the performance standards of section 4.14 must be conducted within an enclosed building.
- Certified engineer's report required for industrial uses
Each prospective use of an industrial or manufacturing character must submit a certified engineer's report pursuant to section 4.14.5.
- Public art location
Public art must be located outside of buildings and be completely visible from the public right-of-way or on a publicly viewable façade. It must be permanently fixed, outside of sight distance triangles.
- Long-term bicycle parking must be covered
Long-term bicycle parking must be covered and within a locked room or locker, etc.
- Maximum block face length without through-access300 ft
No block face may have a length greater than 300 feet without an alley or pedestrian pathway providing through-access to another street, alley, or civic space.
- Maximum duration for temporary uses180 days
Temporary uses must obtain a zoning clearance prior to operation, for operation of up to 180 days. Temporary use zoning clearances may not be renewed.
- Maximum number of full-time employees20 employees
Any individual artisan manufacturing establishment may not employ more than 20 full-time employees or the equivalent part-time employees.
- Maximum façade segment length ratio to building heightMaximum heightThe tallest a building may be, given in feet, in storeys, or both — whichever binds first. (boulevard, avenue, pedestrian passage, civic space)2 times building heightMaximum heightThe tallest a building may be, given in feet, in storeys, or both — whichever binds first.
No building façade segment facing a boulevard, avenue, pedestrian passage, or civic space may exceed double the building height proposed without a physical or visual break in the plane of the façade.
- Maximum façade segment length ratio to building heightMaximum heightThe tallest a building may be, given in feet, in storeys, or both — whichever binds first. (through corridor)4 times building heightMaximum heightThe tallest a building may be, given in feet, in storeys, or both — whichever binds first.
No building façade segment facing a through corridor may exceed four times the building height proposed without a physical or visual break in the plane of the façade.
- Maximum floor area for live-work dwelling unitDwelling unitOne independent home: its own kitchen, bathroom and entrance.3,000 sqftsq ftSquare feet. An acre is 43,560 sq ft; a typical suburban lot is 7,000–10,000.
Live-work dwelling units may have a maximum floor area of 3,000 square feet.
- Maximum residential ground floor façade percentage66.67 pct
No more than two-thirds of the ground floor street facing façade of a single building may be occupied by multiple-family or single-family attached residential uses.
- Ground story transparencyGround-floor transparencyThe share of a ground-floor street wall that must be windows rather than blank surface. measurement
Ground story transparency is measured between two and 12 feet above the abutting sidewalk.
- Minimum percentage of street frontageFrontageThe length of a lot line that touches a public street. built within build-to range66 pct
At least 66 percent of a site's street frontage must be built within the build-to range, with the exception of frontage along through corridors.
- Minimum ceiling heightMaximum heightThe tallest a building may be, given in feet, in storeys, or both — whichever binds first. for commercial space in live-work unit12 ft
The commercial or manufacturing space in a live-work dwelling unit must have a ceiling height of at least 12 feet.
All off-street parking should be located to the rear of buildings.
- Outdoor storage screening
Any materials stored outdoors, with the exception of outdoor display for advertisement, must be hidden behind an opaque fence to screen the ground-level view from any public right-of-way or any residential use, and materials may not be piled or stacked higher than the opaque fence.
- Certificate of appropriateness required
Developments must receive a certificate of appropriateness before a building permit is issued.
- On-street parking required on local streets in Core
On-street parking is not permitted on boulevards and is required on local streets in the Core character area.
- Mechanical and service elements must be screened
The following elements must be screened from view from through corridors, boulevards, avenues, local streets, pedestrian passages, and civic spaces: refuse collection, dumpsters, recycling bins, mechanical equipment, etc.
- Maximum distance from main entrance for short-term bicycle parking50 ft
Required short-term bicycle parking must be visible from nearby bikeways and located within fifty feet of the main building entrances.
- Streets must be constructed to meet section 20C.7
Streets that provide site access and/or connectivity to adjacent properties must be constructed or upgraded to meet the requirements of section 20C.7 and be completed prior to commencement of the use, issuance of a zoning clearance, or issuance of a Certificate of Occupancy for the first phase of development.
Parking
- Minimum setbackSetbackThe distance a building must be held back from a lot line. for surface parking from right-of-way10 ft
Surface parking must be located at least 10 feet from the right-of-way to allow for adequate screening.
- Pick-up/drop-off zone requirement
Uses requiring 20 or more parking spaces must dedicate at least one space per 20 provided spaces as a rideshare, cab, and delivery pick-up or drop-off zone.
From the ordinance
The uses permitted in each character area are listed in Table 1.