Richmond, California · General provision

15.04.610.440

Extracted standards

14 individual requirements pulled out of this section’s prose, each with the sentence it came from.

Lighting

Noise

  • Noise standards

    All WECS are subject to the noise standards of Article 15.04.608 (Performance Standards).

Other

  • WECS with a rated microturbine capacity up to 25 kW are permitted in all zoning districts subject to a conditional use permit except as provided below.

  • Electromagnetic interference

    The WECS must be designed, installed, and operated so that no disrupting electromagnetic interference is caused. Disruptive interference from the facility must be promptly rectified to include the discontinued operation of one or more WECS.

  • Exemptions

    Microturbines that generate two kW or less of electrical energy each, to a maximum cumulative total of 10 kW per lot; and WECS that generate less than 10 kW per system only require approval of an administrative use permit.

  • Guy wire requirements

    Anchor points of any guy wires for a system tower must be located within the property that the system is located on. Guy wires must not cross any above-ground electric transmission or distribution lines. The points of attachment for the guy wires must be either enclosed by a fence six feet high or sheathed in bright orange or yellow coverings from three to eight feet above the ground.

  • Maintenance records

    Maintenance and inspection records shall be maintained on the site and shall be made available for inspection by the building official on request.

  • To prevent harmful wind turbulence from existing structures, the lowest extension of any horizontal axis blade must be at least 30 feet above the highest structure or tree within a 250-foot radius. Modification of this standard may be allowed when the applicant demonstrates that a lower height will not jeopardize the safety of the system.

  • Non-reflective color

    Structural components, including, without limitation, towers, blades, and fencing must be of a non-reflective, unobtrusive color.

  • Notice requirements

    At least one notice shall be posted with the following information: Maximum power output (kW), rated voltage (volts) and current; Normal and emergency shutdown procedures; The maximum wind speed the WECS in automatic, unattended operation can sustain without damage to structural components or loss of the ability to function normally; and Emergency telephone numbers. No advertising sign or logo can be placed or painted on any WECS or tower.

  • Rotor safety

    Each WECS must be equipped with both manual and automatic controls to limit the rotational speed of the blade within the design limits of the rotor.

  • Tower access requirements

    Towers must either: Have tower-climbing apparatus located no closer than 12 feet from the ground; Have a locked anti-climb device installed on the tower; Be completely enclosed by a locked, protective fence at least six feet high; or Have a tower-access limitation program approved by the review authority.

  • Utility notification

    For interconnected systems, no wind turbine can be installed until evidence has been given to the Zoning Administrator that the electric utility service provider has been notified and has indicated that the proposed interconnection is acceptable. On-site electrical wires associated with the system must be installed underground, except for 'tie-ins' to the electric utility service provider and its transmission poles, towers, and lines.

  • Vertical axis separation

    Vertical axis systems must be placed at a distance of at least 10 rotor diameters from any structure or tree. A modification may be granted by the Zoning Administrator or Planning Commission for good cause shown, however, in no case can the turbine be located closer than three blade diameters to any occupied structure.

From the ordinance

WECS with a rated microturbine capacity up to 25 kW are permitted in all zoning districts subject to a conditional use permit except as provided below.
15.04.610.440